Bioaerosol Samplers
Sampling viable, culturable airborne micro-organisms — bacteria, fungi, viruses
Diese Seite gibt es auch auf Deutsch.
Air sampling consumables are the sampling media and accessories for occupational and environmental air monitoring — the medium that captures each contaminant plus the supplies around it. The range spans sorbent tubes and passive samplers for gases and vapours, filter cassettes and cyclones for particulate, liquid impingers and impactors for bioaerosols, and wipes and swabs for surface and skin sampling — mostly from SKC.
Choose your technology
Sampling viable, culturable airborne micro-organisms — bacteria, fungi, viruses
For gases and vapours, not particulate, bioaerosol or surface contamination.
Collecting airborne dust, fibres and particulate onto filters or samplers.
Assessing contamination settled on surfaces and skin, not airborne
Mains bioaerosol pump to 62 L/min for BioSampler liquid impingement; two mounts run two samplers.
to 62 L/min · mains · 7.25 kg
SKC
Glass swirling-liquid impinger collecting into water or ViaTrap oil; autoclavable and reusable for up to 8 h.
12.5 L/min · glass · to 8 h
SKC
Single-stage cascade impactor depositing organisms onto agar plates at 28.3 L/min; meets NIOSH 0800/0801.
28.3 L/min · D50 0.6 µm
SKC
Reagent-coated filters preloaded in cassettes to trap aldehydes, amines and acids without impinger liquids.
37 mm cassette · packs of 10
SKC
Glass and PFA bubbler bottles drawing air through a liquid; 25 mL midget, fritted or spill-resistant.
25 mL · 170–200 µm frit
SKC
Broadband VOC Chek 575 badge with sampling rates for 300+ compounds; choice of charcoal or Anasorb 747.
350 mg charcoal · 300+ VOCs
SKC
Diffusive sampler for sub-ppb to ppt VOCs and SVOCs; a pump-free thermal-desorption alternative to EPA TO-17.
5 sorbents · sub-ppb to ppt
SKC
Single-use badge for formaldehyde and aldehydes using 2,4-DNPH chemistry; meets OSHA 1007 and ISO 16000-4.
28.6 mL/min · LOD 2 ppb
SKC
Single-use badge for sulphur dioxide and/or nitrogen dioxide; TEA chemistry as in active OSHA ID-182.
SO2 15.2 · NO2 17.3 mL/min
SKC
Single-use ammonia badge with sulphuric-acid tape; chemistry as in OSHA ID-188 and NIOSH 6016, 0.1–100 ppm.
39.92 mL/min · 0.1–100 ppm
SKC
Ethylene oxide badge using the same sorbent as active OSHA 1010; ideal for hospitals and sterile-supply sites.
21.2 mL/min · 0.1–4 ppm
SKC
Miniature HCN badge specified in OSHA Method 1015; soda-lime sorbent loads from a vial in the field.
28.4 mL/min · 0.44–20 ppm
SKC
Reusable-holder badge for elemental mercury vapour (TWA); Anasorb C300 capsule, validated to OSHA ID-140.
Anasorb C300 · up to 120 h
SKC
Colour-change strips giving a 10-minute visual read of ozone from under 45 to over 105 ppb — no pump or lab.
45–105 ppb · 10-min read
SKC
Pump-free diffusive TD tube for outdoor benzene and VOC monitoring; sorbent Carbopack X or Anasorb GCB1.
Carbopack X/GCB1 · EPA 325A
SKC
Classic 51 µm Tedlar film for VOCs, referenced in many EPA methods; rated -72 to 107 °C in 0.5 to 100 L sizes.
51 µm · -72 to 107 °C
SKC
Specially cleaned 4-ply 127 µm foil, low VOC and sulphur background; good stability for low-ppm VOCs.
4-ply · 127 µm · 48-h H2S
SKC
Bags with a low-resistance mouthpiece fitting for human-breath VOC and VSC sampling; Tedlar or FlexFoil PLUS.
1 L · Tedlar/FlexFoil PLUS
SKC
Rigid box that fills a sample bag by vacuum so the sample never passes through the pump; for 1 to 25 L bags.
SKC
Made-to-order bags in any material — Tedlar, FlexFilm or FlexFoil — with your choice of size and fitting.
SKC
Economical 4-ply 127 µm foil for VOCs, CO, CO2, methane and SF6; low sulphur background, 48-h H2S stability.
4-ply · 127 µm · low sulphur
SKC
Polar sorbent for methanol, amines, acids and mercaptans; treated grades collect aldehydes and ammonia.
Silica gel · 6–10 mm OD
SKC
SKC proprietary sorbents: 747 carbon for polar organics and ketones, plus CSC charcoal and GCB grades.
Anasorb 747 / CSC / GCB
SKC
Coconut-shell charcoal, high surface area for a broad range of non-polar organic vapours.
Coconut charcoal · 6–10 mm OD
SKC
Porous-polymer sorbent for mid-to-high-boiling compounds; low background, hydrophobic, for thermal desorption.
Tenax TA & GR · EPA TO-17
SKC
Hydrophobic porous-polymer resin XAD-2/4/7 for soluble organics and pesticides; many coated variants.
XAD-2, XAD-4, XAD-7
SKC
Porous polymer for low-boiling hydrocarbons and benzene; grade 102 traps chlorinated pesticides.
Chromosorb 102 / 106
SKC
Foam plugs for semi-volatiles: low-volume tubes to 24 h or high-volume tubes for ambient PCBs and PAHs.
22×100 or 65×125 mm
SKC
Porous polymers of graded polarity (P, Q, T, N); the N grade is used to monitor volatile nitriles.
Porapak P, Q, T, N
SKC
Combined filter and two-bed sorbent tube collecting aerosols and vapours — pesticides, explosives, glycols.
Filter + 2 sorbent beds
SKC
Single- and multi-bed tubes for sub-ppb VOCs in ambient air; purged or unpurged, EPA and MDHS methods.
¼ × 3½ in · EPA/MDHS
SKC
Diffusive stainless steel TD tubes for 14-day fenceline benzene monitoring; meet EPA 325A and MDHS 104.
89 × 6.35 mm · EPA 325A
SKC
Niche sorbents in one range: carbon beads, Florisil, molecular sieve, firebrick, soda lime and VOST traps.
SKC
Made-to-order solvent- and thermal-desorption tubes built to your sorbent, size and packing specification.
SKC
Sampling-train hardware: low-flow adaptors and CPCs, tube holders and covers, tube breakers and field tools.
SKC
Single-use four-impactor sampler for respirable or thoracic PM at 2, 4 or 8 L/min; gravimetric or chemical.
37 mm filter · 2/4/8 L/min
SKC
Empty two- and three-piece filter housings — clear styrene, solvent-resistant or conductive; leak-tested.
25, 37, 47 mm · 2 or 3-piece
SKC
Self-sealing, tamper-evident bands with a writable surface for sample ID; six colours, 25 and 37 mm.
25 & 37 mm · 6 colours
SKC
Reusable in-line and open-face holders from 13 to 47 mm in polypropylene, Delrin, polycarbonate or PFA.
13, 25, 37, 47 mm
SKC
Backing pads and screens under the filter — cellulose, porous plastic or stainless-steel mesh, 25 to 47 mm.
25, 37 and 47 mm
SKC
Solu-CAP and Accu-CAP dome capsules that capture the whole sample and end cassette wall losses; 37 mm.
37 mm · 0.8 µm MCE
SKC
Cases, petri slides, glass jars and Filter-Keeper clamshells for storing and transporting filters to 47 mm.
SKC
Handling tools — forceps, SureSeal openers, filter lifters, collar clips, tubing, adaptors and sample labels.
SKC
Hydrophilic standard for airborne metals and asbestos fibre counting; dissolves fully for AAS/ICP.
0.45–5.0 µm · 13–47 mm · MCE
SKC
Hydrophobic and solvent-resistant, low tare mass — for size-selective samplers and humid aerosols to 260 °C.
0.3–10 µm · 13–47 mm · PTFE
SKC
Low-tare, hydrophobic media for silica, metals and dust; meets OSHA ID-215 for hexavalent chromium.
5.0 µm · 25–47 mm · PVC
SKC
Smooth-surface film for light and electron microscopy; thin, non-staining, very low tare, to 140 °C.
0.4–0.8 µm · 25–47 mm
SKC
Pure metallic-silver media, inert to 500 °C — for X-ray diffraction of silica and stack sampling.
0.45–0.8 µm · 25–47 mm
SKC
Binder-free borosilicate depth media for high-flow gravimetric sampling; 1.0 µm nominal, autoclavable.
1.0 µm nom. · 13–90 mm · glass
SKC
Heat-treated quartz for elemental/organic carbon and diesel particulate (NIOSH 5040); withstands 1000 °C.
1.2 µm nom. · 25–102 mm
SKC
100% pure ashless cellulose (Whatman Type 40 equivalent) for ashless gravimetric and AA/HPLC methods.
37 mm · ashless · Type 40
SKC
Water-soluble gelatin that keeps microbes viable and dissolves on agar; 3 µm nominal for bioaerosols.
3 µm nom. · 25 & 37 mm
SKC
Preloaded MCE cassettes quality-tested for low fibre background; PCM/TEM asbestos with certificate.
0.45–1.2 µm MCE · 25–37 mm
SKC
Dual-filter cassette that traps isocyanate aerosol and vapour at once; MAMA-coated, 1 L/min for 15 min.
5 µm PTFE + GF · 1 L/min
SKC
Slide-based spore trap; flow sets the 1.5–3.9 µm cut-point for mould counting (ASTM D7391).
1.5–3.9 µm cut · 5–30 L/min
SKC
Separates diesel elemental carbon from coal and respirable dust for NIOSH 5040 analysis.
2 L/min · NIOSH 5040
SKC
Reusable weighable cassette traps the inhalable fraction to 100 µm; foam insert adds respirable.
2 L/min · 100 µm · inhalable
SKC
Porous curved-surface inlet samples inhalable dust and bioaerosols with low wind sensitivity.
4 L/min · 100 µm · inhalable
SKC
Dual-arm headset samples welding fume inside masks and helmets to ISO 10882-1.
13 mm MCE · inhalable
SKC
Conductive-plastic respirable cyclone at 3.0 L/min; grit pot and reusable 25 or 37 mm cassette.
3.0 L/min · 4 µm · respirable
SKC
Multi-inlet respirable cyclone unaffected by wind; 4 µm cut at 2.75 L/min into 25 or 37 mm cassette.
2.75 L/min · 4 µm · respirable
SKC
Single-inlet Dorr-Oliver-equivalent cyclone at 2 L/min; also runs the DPM cassette.
2 L/min · 4 µm · respirable
SKC
Aluminium cyclone with sharp respirable cut for NIOSH 7500 silica; 25 and 37 mm versions.
2.5 L/min · 4 µm · respirable
SKC
Cowled sampling head with 25 mm gridded filter for asbestos fibre counting; plastic or aluminium cowl.
25 mm · 0.8 µm MCE · fibres
SKC
Four impactors in one unit match the respirable or thoracic convention; 2, 4 or 8 L/min models.
2–8 L/min · resp./thoracic
SKC
Impaction sampler for PM2.5 or PM10 indoor air; three flow versions at 2, 4 or 10 L/min.
PM2.5/PM10 · 2, 4, 10 L/min
SKC
Modular single-stage impactor for PM2.5, PM10 or PM Coarse at 3 L/min; weighs only 71 g.
3 L/min · PM2.5/PM10/Coarse
SKC
Ambient PM2.5, PM10 or PM Coarse impactor at 10 L/min onto a 47 mm filter, with rain cover.
10 L/min · PM2.5/PM10 · 47 mm
SKC
Cascade impactor collects five size fractions (2.5 to 0.25 µm) at 9 L/min without impaction grease.
9 L/min · 5 stages to 0.25 µm
SKC
Collects inhalable aerosol and vapour together at 1 L/min for mixed-phase compounds; meets EN 13936.
1 L/min · inhalable + vapour
SKC
Personal real-time monitor with interchangeable heads and an in-line 37 mm cassette for gravimetric back-up.
0.01–200 mg/m³ · 0.1–100 µm
SKC
Combines a gravimetric sampling pump and optical sensor with a colour touch screen; runs over 22 hours.
0.001–500 mg/m³ · 22 h
SKC
Passive dust monitor that becomes an active gravimetric sampler when paired with a 2 L/min pump.
0.01–200 mg/m³ · 2 L/min
SKC
Simple handheld survey tool giving instantaneous respirable dust readings on two selectable ranges.
0.01–200 mg/m³ · 0.1–50 µm
SKC
Weatherproof ambient monitor with interchangeable PM10, PM2.5, PM1.0 and TSP heads; runs up to 24 hours.
0.001–20 mg/m³ · 4 L/min
SKC
Fixed-point monitor with interchangeable PM1, PM2.5, respirable and PM10 impactors at 2 L/min.
0.001–20 mg/m³ · 2 L/min
SKC
Multi-sensor perimeter station measuring PM10 and PM2.5 plus up to 14 air parameters simultaneously.
Up to 14 sensors · 1–3 L/min
SKC
Nozzle cassettes vacuuming settled asbestos or fungal spores from carpet and irregular surfaces at 10 L/min.
0.45 µm MCE · ASTM D5755
SKC
Flexible adhesive slide that lifts mould and dust from surfaces; unbreakable and serialised for the lab.
SKC
Robust water-moistened wipes for lead and surface metals that fully dissolve in acid digestion for recovery.
ASTM E1792 · NIOSH 9102
SKC
All-in-one OSHA wipe-method kit for metals, pesticides, amines and corrosives — solvents not included.
SKC
Sterile rayon swabs in transport tubes for microbial contamination on grills and other irregular surfaces.
SKC
Colour-change indicators for amines, isocyanates, phenols and nickel on surfaces or skin — instant read.
SKC
Pads worn inside gloves that colour-change at breakthrough; sensitive to 3–5 µg for amines and isocyanates.
3–5 µg · amines/isocyanates
SKC
Rhodizonate spot test for lead on skin and surfaces; instant pink bloom, meets NIOSH 9105.
18 µg lead · NIOSH 9105
SKC
Potassium rhodizonate swabs for lead on surfaces; pink or red at 1 µg or more, 10 tests per kit.
≥ 1 µg lead · 10 swabs
SKC
Low-ash, acid-hardened paper tabs for wipe sampling of settled metals; OSHA ID-121/125G/206.
SKC
Manila paper area templates in 10 × 10 cm and 30.5 × 30.5 cm; larger size meets HUD lead guidelines.
10×10 cm · 30.5×30.5 cm
SKC
Bundled SWYPEs, PERMEA-TEC pads and decontamination solutions for one target compound group; OSHA validated.
SKC
Biodegradable clean-up kits for aromatic amine and isocyanate spills; 15 L of solution plus confirming SWYPEs.
15 L solution · SWYPE 3–5 µg
SKC
Biodegradable solutions that decontaminate surfaces of aromatic amines and isocyanates; 3.75 L or 650 ml.
SKC
Skin cleanser that lifts water-insoluble amines, pesticides and resins without abrading the skin barrier.
SKC
Colorimetric wet-wipe-spray test for methamphetamine hot spots; qualitative, no training needed.
15–5000 µg/100 cm² · 12 tests
SKC
Immunoassay wipe kit for semi-quantitative methamphetamine down to 50 ng; four sensitivity levels.
from 50 ng (0.05 µg/100 cm²)
SKCStart from what you need to capture, because the medium follows the contaminant. Gas and vapour sampling covers sorbent tubes, diffusive passive samplers, liquid impingers and whole-air sample bags. Particulate sampling covers membrane and depth filters, cassette hardware and size-selective cyclones for dust and fibres.
Bioaerosol samplers collect viable, culturable micro-organisms, either into liquid or onto agar plates. Surface and skin sampling is the section for contamination that has settled rather than stayed airborne: metals wipes, microvacuum cassettes and colorimetric spot tests.
Sorbent tube sampling, filter cassettes and impingers are pumped: the pump draws sample air through the medium, so its flow rate must match what the method specifies. Passive samplers and wipes need no pump. Compare the flow ranges of the air sampling pumps before you order media for a pumped method.
Our application engineers aim to reply within 3 business hours.