Particulate Sampling

Particulate samplers collect airborne dust, fibres and particulate onto filters for gravimetric or chemical analysis. The section spans membrane and depth filters, cassette hardware, size-selective cyclones and impactors, and direct-reading dust monitors — from SKC.

Choose your technology

  • SureSeal Cassette Blanks

    Empty two- and three-piece filter housings — clear styrene, solvent-resistant or conductive; leak-tested.

    25, 37, 47 mm · 2 or 3-piece

    SKC
    Details →
  • Cassette Shrink Bands

    Self-sealing, tamper-evident bands with a writable surface for sample ID; six colours, 25 and 37 mm.

    25 & 37 mm · 6 colours

    SKC
    Details →
  • Cassette and Filter Holders

    Reusable in-line and open-face holders from 13 to 47 mm in polypropylene, Delrin, polycarbonate or PFA.

    13, 25, 37, 47 mm

    SKC
    Details →
  • Filter Supports

    Backing pads and screens under the filter — cellulose, porous plastic or stainless-steel mesh, 25 to 47 mm.

    25, 37 and 47 mm

    SKC
    Details →
  • Cassette Inserts

    Solu-CAP and Accu-CAP dome capsules that capture the whole sample and end cassette wall losses; 37 mm.

    37 mm · 0.8 µm MCE

    SKC
    Details →
  • Cassette and Filter Storage

    Cases, petri slides, glass jars and Filter-Keeper clamshells for storing and transporting filters to 47 mm.

    SKC
    Details →
  • Filter Sampling Accessories

    Handling tools — forceps, SureSeal openers, filter lifters, collar clips, tubing, adaptors and sample labels.

    SKC
    Details →

Particulate Sampling

1 model

How do I choose a particulate sampler for airborne dust?

Start from the result you need: a mass concentration for a defined size fraction, a chemical analysis, or an instant reading. For gravimetric or chemical work the sample goes onto a filter. The filters and cassettes range covers membrane and depth media, 13 to 102 mm diameters, 0.3 to 10 µm pore sizes; pick the material and pore for your analyte. Filter and cassettes accessories add holders, supports, blanks and storage, but no filter media.

Which size fraction do I sample: respirable, thoracic or inhalable?

Airborne dust sampling is usually specified by size fraction. Particle size-selective sampling uses cyclones, impactors and cowled inlets to separate the fraction onto the filter: respirable with a 50% cut-point of 4 µm, inhalable to 100 µm (IOM, Button), and PM10, PM2.5 and PM1.0 impactors. For respirable or thoracic PM, the disposable parallel particle impactors are a single-use four-impactor sampler at 2, 4 or 8 L/min.

Do I need a direct-reading dust sampler or monitor?

When you want instant values without a lab weighing step, use particulate monitors. They read concentration from 0.001 to 500 mg/m³ by optical light-scattering, with ±10% to gravimetric, and show instantaneous, TWA, STEL, min and max values.

Questions about these products?

Our application engineers aim to reply within 3 business hours.

Ask an engineer