Aluminium Respirable Dust Cyclone
The SKC aluminium cyclone is a lightweight sampler used with a filter loaded into a three-piece filter cassette, giving sharp size selection between respirable fractions at 4 or 5 µm.
The SKC aluminium cyclone is a small, lightweight sampler that gives sharp size selection for the respirable fraction. It is available in 25 mm and 37 mm versions and runs at 2.5 L/min. It eliminates adverse electrostatic effects, allowing the cyclone to sample particles more efficiently. It belongs to the particle size selective sampling range.
How does the aluminium cyclone select respirable dust?
Insert it into the middle ring of an open-face three-piece cassette loaded with an appropriate filter. The filter collects the respirable particles, while larger particles fall into the grit pot to be discarded.
The 50% cut-point is 4 µm at 2.5 L/min and 3.5 µm at 2.8 L/min.
Which methods specify the aluminium cyclone?
It is specified in NIOSH Method 7500 for silica and NIOSH 0600 for respirable particulates.
Which cyclone for the 25 mm or 37 mm filter?
Both sizes use filters in 3-piece cassettes. The category also lists a respirable dust cyclone.
| Parameter | Value |
|---|---|
| Flow Rate | 2.5 L/min |
| 50% Cut-point | 4 µm at 2.5L/min 3.5 µm at 2.8 L/min |
| Material | Aluminium |
| Sample media | 25 or 37 mm filters in 3-piece cassettes |
| Tubing | 1/4inch (6.25 mm) ID |
| Dimensions | 6.6 x 3.8 cm |
| Description | Pack Size | Part Number | |
|---|---|---|---|
| 25 mm Respirable Dust Aluminium Cyclone, with grit pot. | Each | 225-01-01 | |
| 37 mm Respirable Dust Aluminium Cyclone, with grit pot. | Each | 225-01-02 |
| Description | Pack Size | Part Number | ||
|---|---|---|---|---|
| Filter Transport Cassette, 25 mm, conductive plastic | 10 | 225-67-10 | | |
| Three-piece Filter Cassette Blanks, 25 mm | 50 | 225-3-25LF | | |
| Three-piece Filter Cassette Blanks, 37 mm | 10 | 225-3LF | | |
| Filter Cassette/Cyclone Holder includes: 0.9 m (3 ft) of 1/4 inch ID Tygon tubing and a 25 mm adaptor ring, for attaching a DPM or standard filter cassette to a worker’s clothing in the breathing zone. May be used with or without a cyclone | Each | 225-1 | | |
| Standard-size Multi-purpose Calibration Chamber | Each | 225-111 | | |
| Calibration Adaptor, for 25 mm and 37 mm cyclones. Allows 1/4 inch ID Tygon tubing to be attached to the cyclone for simple calibration | Each | 225-01-03 | | |
| Replacement Grit Pot for Aluminium Cyclones | 25 | P225013 | | |
| Replacement O-Ring for 37 mm Aluminium Cyclone, 225-01-02 | 5 | P22501 | | |
| Replacement O-Ring for 25 mm Aluminium Cyclone, 225-01-01 | 5 | P3226 | |
Questions about this product?