Filter And Cassettes Accessories
7 models
Respirable dust cyclones, impactors and cowled inlets fractionate aerosol by aerodynamic diameter onto a collection filter for gravimetric or chemical analysis. They span respirable (4 µm cut), thoracic, inhalable (100 µm) and PM10/PM2.5/PM1.0 fractions, plus fibre and diesel-particulate heads — from SKC.
Separates diesel elemental carbon from coal and respirable dust for NIOSH 5040 analysis.
2 L/min · NIOSH 5040
SKC
Reusable weighable cassette traps the inhalable fraction to 100 µm; foam insert adds respirable.
2 L/min · 100 µm · inhalable
SKC
Porous curved-surface inlet samples inhalable dust and bioaerosols with low wind sensitivity.
4 L/min · 100 µm · inhalable
SKC
Dual-arm headset samples welding fume inside masks and helmets to ISO 10882-1.
13 mm MCE · inhalable
SKC
Conductive-plastic respirable cyclone at 3.0 L/min; grit pot and reusable 25 or 37 mm cassette.
3.0 L/min · 4 µm · respirable
SKC
Multi-inlet respirable cyclone unaffected by wind; 4 µm cut at 2.75 L/min into 25 or 37 mm cassette.
2.75 L/min · 4 µm · respirable
SKC
Single-inlet Dorr-Oliver-equivalent cyclone at 2 L/min; also runs the DPM cassette.
2 L/min · 4 µm · respirable
SKC
Aluminium cyclone with sharp respirable cut for NIOSH 7500 silica; 25 and 37 mm versions.
2.5 L/min · 4 µm · respirable
SKC
Cowled sampling head with 25 mm gridded filter for asbestos fibre counting; plastic or aluminium cowl.
25 mm · 0.8 µm MCE · fibres
SKC
Four impactors in one unit match the respirable or thoracic convention; 2, 4 or 8 L/min models.
2–8 L/min · resp./thoracic
SKC
Impaction sampler for PM2.5 or PM10 indoor air; three flow versions at 2, 4 or 10 L/min.
PM2.5/PM10 · 2, 4, 10 L/min
SKC
Modular single-stage impactor for PM2.5, PM10 or PM Coarse at 3 L/min; weighs only 71 g.
3 L/min · PM2.5/PM10/Coarse
SKC
Ambient PM2.5, PM10 or PM Coarse impactor at 10 L/min onto a 47 mm filter, with rain cover.
10 L/min · PM2.5/PM10 · 47 mm
SKC
Cascade impactor collects five size fractions (2.5 to 0.25 µm) at 9 L/min without impaction grease.
9 L/min · 5 stages to 0.25 µm
SKC
Collects inhalable aerosol and vapour together at 1 L/min for mixed-phase compounds; meets EN 13936.
1 L/min · inhalable + vapour
SKCThe four respirable cyclones all give a 4 µm cut and differ in flow and build. The GS-1 cyclone is a single-inlet, Dorr-Oliver-equivalent design at 2 L/min. The GS-3 cyclone is multi-inlet and unaffected by wind, at 2.75 L/min. The plastic cyclone is conductive plastic at 3.0 L/min with a grit pot, and the aluminium cyclone runs at 2.5 L/min for NIOSH 7500 silica.
For diesel exposure, the DPM cyclone separates diesel elemental carbon from coal and respirable dust for NIOSH 5040 analysis.
The IOM sampler traps the inhalable fraction to 100 µm in a reusable weighable cassette. The Button sampler uses a porous curved-surface inlet with low wind sensitivity for inhalable dust and bioaerosols. The IFV Pro sampler collects inhalable aerosol and vapour together at 1 L/min. Parallel particle impactors match the respirable or thoracic convention in 2, 4 or 8 L/min models.
For fibres and welding fume, see the cowled asbestos sampling head and face level sampling headset (ISO 10882-1).
The IMPACT sampler takes ambient PM2.5, PM10 or PM Coarse at 10 L/min onto a 47 mm filter. The Personal Environmental Monitor samples PM2.5 or PM10 indoor air, and the Personal Modular Impactor is a single-stage unit at 3 L/min. For several fractions at once, the Sioutas cascade impactor collects five size fractions at 9 L/min.