Air Sampling Consumables
0 models
GASTEC detector tubes are colorimetric tubes used with a piston hand pump for on-the-spot measurement of gases and vapours. Direct-reading tubes for short-term spot checks, passive dosi-tubes for time-weighted averages, plus Polytec, Pyrotec, breathing-air, and soluble-ion tubes — from GASTEC.
Direct-reading tubes for short-term spot measurement and low-level detection of gases and vapours.
GASTEC
Piston hand pump drawing 50 or 100 mL per stroke, plus pyrolyzer, hoses and probes for the tube system.
50 or 100 mL/stroke · 270 g
GASTEC
Passive diffusion tubes for time-weighted-average exposure over a shift; no pump, chart or lab needed.
GASTEC
Multi-layer tubes reading 1–8 substances at once; qualitative screening of unknown gas mixtures.
1–8 layers · qualitative
GASTEC
For compounds needing thermal breakdown first; used with the GST_840 pyrolyzer for fluorochlorocarbons.
GASTEC
Emergency kit: 12 detector tube types, pump, smoke tester and hose to identify unknown gases by flowchart.
12 tube types · 5 kg kit
GASTEC
Immerse in solution to read dissolved ions by capillary action; for soil and water contamination checks.
GASTEC
Tubes for compressed breathing-air quality: CO, CO2, water vapour, oil mist and nitrogen oxides.
GASTEC
Syringe injects a fixed sample into the tube; for high-concentration carbon dioxide and propane.
CO2 to 100% · propane to 2%
GASTEC
Kit measures four breathing-air contaminants at once — CO, CO2, water vapour and oil mist; no power.
4 contaminants · no power
GASTEC
Squeeze-bulb smoke tubes reveal the direction of slight air currents and map vapour spread indoors.
6 smoke tubes/pack
GASTECPick by the question you are asking. For a quick reading of a known gas or vapour, Gastec colour gas detector tubes are direct-reading. For an exposure averaged over a shift, Gastec passive dosi-tubes need no pump. For an unknown mixture, Gastec Polytec tubes read 1–8 substances at once for qualitative screening. Compounds that need thermal breakdown first, such as fluorochlorocarbons, use Gastec Pyrotec tubes with the GST_840 pyrolyzer.
Colour change detection tubes draw the sample through a reagent layer that changes colour when the target gas is present. The Gastec gas sampling pumps supply the stroke. For emergencies, the Gastec toxic gas detection system helps identify unknown gases by flowchart.
Gastec Airtec tubes check compressed breathing-air quality. Gastec soluble ion tubes read dissolved ions in soil and water checks. Gastec injection type tubes handle high-concentration carbon dioxide and propane.
Our application engineers aim to reply within 3 business hours.