Gas And Vapour Sampling

Gas and vapour sampling media collect airborne gases and vapours for later laboratory analysis. The family spans pumped sorbent tubes, diffusive passive samplers, liquid impingers and whole-air sample bags, plus reagent-coated filters for reactive compounds — from SKC.

Choose your technology

Impingers

1 model
  • Impingers

    Glass and PFA bubbler bottles drawing air through a liquid; 25 mL midget, fritted or spill-resistant.

    25 mL · 170–200 µm frit

    SKC
    Details →

Sample Bags

6 models
  • Tedlar Sample Bags

    Classic 51 µm Tedlar film for VOCs, referenced in many EPA methods; rated -72 to 107 °C in 0.5 to 100 L sizes.

    51 µm · -72 to 107 °C

    SKC
    Details →
  • FlexFoil PLUS Sample Bags

    Specially cleaned 4-ply 127 µm foil, low VOC and sulphur background; good stability for low-ppm VOCs.

    4-ply · 127 µm · 48-h H2S

    SKC
    Details →
  • Breath-gas Analysis Bags

    Bags with a low-resistance mouthpiece fitting for human-breath VOC and VSC sampling; Tedlar or FlexFoil PLUS.

    1 L · Tedlar/FlexFoil PLUS

    SKC
    Details →
  • SKC Vac-U-Chamber

    Rigid box that fills a sample bag by vacuum so the sample never passes through the pump; for 1 to 25 L bags.

    SKC
    Details →
  • Custom Sample Bags

    Made-to-order bags in any material — Tedlar, FlexFilm or FlexFoil — with your choice of size and fitting.

    SKC
    Details →
  • Standard FlexFoil Sample Bags

    Economical 4-ply 127 µm foil for VOCs, CO, CO2, methane and SF6; low sulphur background, 48-h H2S stability.

    4-ply · 127 µm · low sulphur

    SKC
    Details →

Sorbent tubes

14 models

Gas And Vapour Sampling

1 model
  • Coated (Treated) Filters

    Reagent-coated filters preloaded in cassettes to trap aldehydes, amines and acids without impinger liquids.

    37 mm cassette · packs of 10

    SKC
    Details →

How do I sample vapours with a sorbent tube and pump?

Sorbent tubes are the standard route for organic vapour sampling, including charcoal tube sampling. A pump draws air through a packed sorbent bed, and the trapped vapours are recovered by solvent or thermal desorption for GC or HPLC. Sorbents span charcoal, silica gel, Anasorb, Tenax and XAD, and the tubes meet OSHA, NIOSH, EPA TO-17 and MDHS methods. Choose the sorbent for your analyte and the desorption format for your laboratory.

Can I sample gases and vapours without a pump?

Yes. Passive samplers collect by diffusion at a validated uptake rate, 15 to 40 mL/min, and are validated to ASTM D6246 and ANSI/ISEA 104. Sampling runs from 15 minutes to 7 days. Besides broadband organic-vapour badges, there are compound-specific samplers for formaldehyde, SO2/NO2, ammonia and ozone, among others.

Which medium suits reactive gases, mists or a grab sample?

For reactive gases and mists, impingers draw air through a collection liquid for wet-chemistry analysis. To keep a whole-air grab sample intact, use sample bags, in sizes from 0.5 to 100 litres. For aldehydes, amines and acids without impinger liquids, the coated (treated) filters come preloaded in cassettes with a reagent coating.

Questions about these products?

Our application engineers aim to reply within 3 business hours.

Ask an engineer