Impingers
1 model
Passive air samplers: diffusive badges and tubes that collect gases and vapours without a pump, at a validated uptake rate, then go to the lab for analysis. The range covers broadband organic-vapour badges and compound-specific samplers for formaldehyde, SO2/NO2, ammonia, ethylene oxide, HCN, mercury and ozone — from SKC.
Broadband VOC Chek 575 badge with sampling rates for 300+ compounds; choice of charcoal or Anasorb 747.
350 mg charcoal · 300+ VOCs
SKC
Diffusive sampler for sub-ppb to ppt VOCs and SVOCs; a pump-free thermal-desorption alternative to EPA TO-17.
5 sorbents · sub-ppb to ppt
SKC
Single-use badge for formaldehyde and aldehydes using 2,4-DNPH chemistry; meets OSHA 1007 and ISO 16000-4.
28.6 mL/min · LOD 2 ppb
SKC
Single-use badge for sulphur dioxide and/or nitrogen dioxide; TEA chemistry as in active OSHA ID-182.
SO2 15.2 · NO2 17.3 mL/min
SKC
Single-use ammonia badge with sulphuric-acid tape; chemistry as in OSHA ID-188 and NIOSH 6016, 0.1–100 ppm.
39.92 mL/min · 0.1–100 ppm
SKC
Ethylene oxide badge using the same sorbent as active OSHA 1010; ideal for hospitals and sterile-supply sites.
21.2 mL/min · 0.1–4 ppm
SKC
Miniature HCN badge specified in OSHA Method 1015; soda-lime sorbent loads from a vial in the field.
28.4 mL/min · 0.44–20 ppm
SKC
Reusable-holder badge for elemental mercury vapour (TWA); Anasorb C300 capsule, validated to OSHA ID-140.
Anasorb C300 · up to 120 h
SKC
Colour-change strips giving a 10-minute visual read of ozone from under 45 to over 105 ppb — no pump or lab.
45–105 ppb · 10-min read
SKC
Pump-free diffusive TD tube for outdoor benzene and VOC monitoring; sorbent Carbopack X or Anasorb GCB1.
Carbopack X/GCB1 · EPA 325A
SKCA passive air sampler collects gases and vapours by diffusion, with no pump. The badges and tubes sample at a validated uptake rate, 15 to 40 mL/min across the range, for anything from 15 minutes to 7 days, and then go to the lab; the ozone test strips are the exception and are read on site. The organic-vapour badges follow ASTM D6246 and ANSI/ISEA 104, and the ethylene oxide badge ANSI/ISEA 104.
For mixed vapours, the organic vapour passive samplers are broadband: the VOC Chek 575 badge has sampling rates for 300+ compounds, with charcoal or Anasorb 747. For trace levels, ULTRA passive samplers cover sub-ppb to ppt VOCs and SVOCs as a pump-free thermal-desorption alternative to EPA TO-17, and passive thermal desorption tubes suit outdoor benzene and VOC monitoring.
UMEX100 samples formaldehyde and aldehydes and meets OSHA 1007 and ISO 16000-4. UMEx 200 covers SO2 and NO2, and UMEx 300 covers ammonia at 0.1–100 ppm. The ethylene oxide badge reads 0.1–4 ppm, and the hydrogen cyanide badge 0.44–20 ppm. The elemental mercury badge samples for up to 120 h. Ozone test strips give a 10-minute visual read from 45–105 ppb, with no pump or lab.