The SKC 575-001 organic vapour passive sampler contains charcoal (350 mg), while the 575-002 contains Anasorb® 747 (500 mg). Both belong to the VOC Chek 575 passive samplers, with sampling rates for over 300 compounds for ppm-level organic vapours. SKC has scientifically validated the sampling rate of the VOC Chek 575 passive samplers along with other critical sampling parameters to meet OSHA/ASTM/ANSI requirements, and they are identified as a viable alternative to active sampling in several OSHA methods. They meet ASTM D6246-08 and ANSI/ISEA 104-1998 (r 2009) standards and belong to the Passive Samplers range.

Which VOC Chek 575 passive sampler fits which compound?

Part numbers by compound, with the OSHA method of the passive sampler:

  • 575-002 for benzene (OSHA 1005), butyl acetates (OSHA 1009), MEK/MIBK (OSHA 1004), toluene (OSHA 111), trichloroethylene/tetrachloroethylene (OSHA 1001) and trimethylbenzene (OSHA 1020)
  • 575-006 for styrene (OSHA 1014): Anasorb® 747 coated with tert-butyl catechol (500 mg)
  • 575-007 for methanol: Anasorb® 747 (500 mg)
  • 575-005 for ethylene oxide: Anasorb® 747 treated with hydrobromic acid (500 mg); see also Ethylene Oxide Passive Samplers

Only SKC offers a choice of sorbents to better target specific contaminants, and proper sorbent selection means no reverse diffusion. Review the Passive Sampling Guide to identify the most appropriate sampler.

What sizes and packs are available?

  • 575-001 (charcoal, 350 mg): packs of 5, 25 (575-001A), 100 (575-001B) and 500 (575-001C)
  • 575-002 (Anasorb® 747, 500 mg): packs of 5, 25 (575-002A), 100 (575-002B) and 500 (575-002C)
  • 575-005: packs of 5, 25 (575-005A) and 500 (575-005C); 575-006 and 575-007: packs of 5
  • Analysis accessories, 10 per pack: 575-048 for 575-001 samplers, 575-049 for 575-002 and 575-007 samplers, 575-051 for 575-005 samplers, 575-052 for 575-006 samplers

Why use VOC Chek 575 passive samplers?

  • Highly accurate and reliable: proven performers in the laboratory and in the field, extensively tested and documented
  • Decrease sampling costs: collect most compounds with one sampler for up to a full 8 hour shift, eliminating multiple trips to the worksite; one sampler + one analysis = money saved
  • SKC sorbents have a larger surface area for higher capacities, and solvent desorption and GC analysis are economical
  • So easy to use: no pump or training required

Questions about this product?

Our application engineers aim to reply within 3 business hours.

Ask an engineer