SKC

Passive Thermal Desorption Tubes

EPA 325A passive sampling tubes with validated sampling rates for benzene, toluene, xylenes, ethylbenzene and many other VOCs

Ask an engineer

SKC Passive Thermal Desorption tubes are EPA 325A passive sampling tubes: an easy and accurate way to sample low-level VOCs over extended periods of time, without a pump. They meet the requirements of EPA 325A regulation for fence-line monitoring of benzene at petroleum refineries with extended sample periods of 14 days. SKC supplies sampling rates for other VOCs for other applications. The tubes are part of the Passive Samplers range.

  • Meets specification of U.S. EPA 325A and UK HSE MDHS 104
  • EPA-validated sampling rates available for benzene, toluene, ethylbenzene, xylenes and many other VOCs
  • Allows for extended sample times for low-level measurements
  • Unique identification number and bar code
  • Airflow direction and cap placement arrow indicators printed on tube
  • Reusable after laboratory conditioning
  • Ideal for establishing average airborne concentrations of additional VOCs of concern

How does an EPA 325A passive sampling tube work?

The tubes are standard-sized SilcoNert 2000® deactivated stainless steel thermal desorption tubes with Swagelok fittings. When deployed, a diffusion cap is connected to one end. The diffusion cap works the same way as a front plate on a passive badge, and a small screen inside keeps out particulates and insects. SilcoNert 2000® is the coating that deactivates the stainless steel EPA 325 Passive TD Tubes for Benzene; it improves corrosion resistance, inertness and hydrophobicity for better detection limits and system performance. Analysis is by GC-FID or GC-MS.

For benzene, the validated uptake rate is 0.67 ±0.06 on Carbopack X and 0.63 ±0.07 on Anasorb GCB1 (mL/min).

Which sorbent: Carbopack X or Anasorb GCB1?

The tubes are filled with pre-conditioned sorbent, either Carbopack X, 400mg, or Anasorb GCB1, 400mg. A pack holds 10 tubes with diffusion caps and brass Swagelok screw caps with PTFE ferrules. Tubes must be used within 30 days of conditioning, and all tubes are conditioned and quality control tested to assure low background. The Specifications tab lists the uptake rates of the other compounds; for most of them they are given for Carbopack X only.

Where are the tubes used?

Applications include:

  • Fenceline monitoring
  • Indoor air sampling
  • Vapour intrusion studies

For outdoor use, tubes are deployed inside a custom-made weatherproof shelter (226-526). It holds up to 4 tubes at a time and keeps them pointing diffusion-cap downwards.

Questions about this product?

Our application engineers aim to reply within 3 business hours.

Ask an engineer