SKC

UMEX100 Passive Sampler CH2O

UMEx 100 passive sampler for formaldehyde: meets OSHA Method 1007 specifications and conforms to EU ISO 16000-4-2004 with highly selective 2,4-DNPH chemistry for easy analysis

Ask an engineer

The UMEx 100 passive sampler for formaldehyde was developed in collaboration with the National Institute of Working Life in Umea, Sweden. Constructed of tough polypropylene, the single-use UMEx 100 contains a tape treated with 2,4-dinitrophenylhydrazine (DNPH) for reliable collection of formaldehyde. It is accurate and reliable, needs no pump or training, and is part of the Passive Samplers range.

How does the UMEx 100 collect formaldehyde?

Formaldehyde forms a stable DNPH-hydrazone on the tape; analysis is by solvent extraction and HPLC with UV detection, a highly sensitive and specific analysis method. Each sampler incorporates a “blank/correction” section in addition to the active sampling section, so there is no need to send extra samplers to the laboratory: sample medium and blank/correction in one unit. Samplers are provided in individual aluminiumised pouches that can be used to transport the sampler to a laboratory after sampling. The shelf-life date is printed on a label on the outside of each pouch for easy inventory management. A clip attaches the UMEx 100 to a worker’s collar for personal sampling, or it can be placed in an appropriate location for area sampling.

  • Small and unobtrusive, with a simple-to-use “on/off” sliding cover
  • Safe: no glass or chemical liquids in the sampler
  • Versatile: suitable for both workplace sampling and long term indoor air sampling
  • Economical low cost sampler

Does the UMEx 100 meet OSHA 1007 and ISO 16000-4?

It meets specifications of OSHA Method 1007 (if sampling in an atmosphere where Formalin is the source of formaldehyde, please contact us), conforms to EU ISO 16000-4-2004 and is referenced in EPA IP-6C. It is validated by OSHA and the Swedish Institute, and its accuracy of ± 25% exceeds OSHA requirements.

Which sampling rate and detection limit does the UMEx 100 have?

The sampling rate is 28.6 ml/min at wind velocity of 5 to 100 cm/sec for 15 minutes to 24 hours, which enhances sensitivity for 15 minute, 8 hour, and 24 hour sampling. For 1 to 7 days it is 20.4 ml/min at wind velocities < 5 cm/sec. Uptake rates are documented for 15 minute to 24 hour samples and for 7 day samples (sampling periods between 24 hours and 7 days have not been evaluated). The limit of detection is low: 2 ppb for 24 hrs and 0.2 ppb for 7 days. The Specifications tab also lists sampling rates for other aldehydes.

The sampler is designed for single use only; do not reuse it. It has a limited shelf-life of 12 months from date of manufacture at < 4°C (39.2°F) and must not be stored with food. Packs hold 10 (500-100) or 25 (500-100A) samplers.

Questions about this product?

Our application engineers aim to reply within 3 business hours.

Ask an engineer