SKC

Passive Thermal Desorption Tubes

SKC passive thermal desorption tubes are diffusive tubes for benzene and other VOCs, deployed for 14-day fenceline monitoring at multiple points around petroleum refinery sites

Ask an engineer

SKC passive thermal desorption tubes offer an easy and accurate way to sample low-level VOCs over extended periods of time. The diffusive tubes for benzene and other VOCs are deployed for 14-day fenceline monitoring at multiple points around petroleum refinery sites. They meet the requirements of EPA 325A regulation for fence-line monitoring of benzene at petroleum refineries with extended sample periods of 14 days. SKC supplies sampling rates for other VOCs for other applications. A weatherproof shelter is available for protecting samplers during outdoor sampling.

  • Meets specification of U.S. EPA 325A and UK HSE MDHS 104
  • EPA-validated sampling rates available for benzene, toluene, ethylbenzene, xylenes and many other VOCs
  • Allows for extended sample times for low-level measurements
  • Unique identification number and bar code
  • Airflow direction and cap placement arrow indicators printed on tube
  • Reusable after laboratory conditioning
  • Ideal for establishing average airborne concentrations of additional VOCs of concern

Applications include fenceline monitoring, indoor air sampling and vapour intrusion studies.

How does a passive thermal desorption tube work?

The tubes are standard-sized SilcoNert 2000® deactivated stainless steel thermal desorption tubes (89 x 6.35 mm) with Swagelok fittings; when they are deployed, a diffusion cap is connected to one end. The diffusion cap works the same way as a front plate on a passive badge, and has a small screen inside which also keeps out particulates/insects. SilcoNert 2000® is used as a coating to deactivate the stainless steel EPA 325 Passive TD Tubes for Benzene. This process improves corrosion resistance, inertness, and hydrophobicity for better detection limits and system performance. Analysis is by GC-FID or GC-MS.

Tubes are deployed inside a custom-made shelter for outdoor use, which can hold up to 4 tubes at a time, and keeps them pointing diffusion-cap downwards.

Which uptake rates are validated for benzene?

For benzene, the validated uptake rates in mL/min are 0.67 ±0.06 with Carbopack X and 0.63 ±0.07 with Anasorb GCB1. The Validated Uptake Rates table lists further compounds. Tube 226-520 is filled with pre-conditioned Carbopack X, 400mg, and supplied with diffusion caps; tubes must be used within 30 days of conditioning.

Note: All tubes are conditioned and quality control tested to assure low background. See the sorbent tubes category for the wider range.