Coated (Treated) Filters
SKC coated (treated) filters are reagent-coated filters preloaded in cassettes, ready to use, meeting agency method specifications and trapping aldehydes, amines and acids without impinger liquids.
SKC offers coated filters to meet a variety of OSHA, NIOSH, ASTM, and international agency methods. SKC coated (treated) filters are ready to use and need no assembly: they come preloaded into cassettes with end plugs and shrink bands.
What are coated (treated) filters used for?
Some chemicals are not effectively trapped by any solid sorbent without special preparation. Chemical coating is carried out on various sorbents to trap aldehydes, nitrogen dioxide, amines and many more compounds. Coated filters make sampling reactive compounds fast and easy, and they are a convenient alternative to wet chemistry methods using impingers. Use them to collect compounds that exist as an aerosol or mist or for some higher boiling vapours.
- Ready to use and time-saving
- Convenient alternative to impinger wet chemistry methods, with no cumbersome collection liquids or glass
- Economical
- No assembly required, with end plugs and shrink bands
- Meet agency method specifications
- Easy personal sampling
- Small package size for short shelf-life product
How do you use a coated filter cassette?
- Unplug the lightweight cassette.
- Insert it into an SKC filter cassette holder, such as those under Cassette and Filter Holders.
- Clip the holder to a worker’s collar.
- Attach it to a personal sampling pump.
Flow rates are typically greater than 1 L/min and sampling times range from 15 minutes to one hour. Most coated filter samples are extracted in solvents and analysed by gas or liquid chromatography.
Which coated filter for hydrogen peroxide or isocyanates?
The part number table lists each chemical with its method. Two examples:
- 225-9030 for hydrogen peroxide, listed for OSHA 1019 and NON 57: two 25 mm quartz filters coated with titanium oxysulphate hydrate in a 25 mm cassette, packs of 10. It also requires sorbent tube 226-193-UC or 226-199-UC for simultaneous, separate sampling of peracetic acid.
- 225-9002 for isocyanates (HDI;2,6-TDI;2,4-TDI) under OSHA 42: one glass fibre filter and cellulose support coated with 1-(2-pyridyl) piperazine. It meets the specifications of OSHA Methods 42 and 47 but contains a higher than specified loading of reagent to increase stability and shelf-life, and traps both vapour and aerosol phases. Storage below 4°C required.
Some isocyanate filters meet multiple ASTM methods; the table refers to ISO-CHEK Cassettes for these.
The methods listed are the most widely used. Coated filters have a limited shelf life and are supplied in 37 mm cassettes unless otherwise noted. The range is part of Gas And Vapour Sampling.
56 entries
| Chemical | Method | Filter; Coating | Pack Size | Part Number | |
|---|---|---|---|---|---|
| Acetic anhydride | OSHA 82 | 2 Glass fibre filters; 1-(2-pyridyl) piperazine | 10 | 225-9009 § | |
| Acetic anhydride | OSHA 102 | 2 Glass fibre filters; veratrylamine and di-n-octyl phthalate | 10 | 225-9010 † | |
| 4-Aminobiphenyl | OSHA 93 | 2 Glass fibre filters; sulphuric acid | 10 | 225-9004 | |
| Aniline | NIOSH 2017 | 2 Glass fibre filters; sulphuric acid | 10 | 225-9004 ¥ | |
| Arsenic, volatile compounds | OSHA ID-1006 | 1 MCE filter and plastic pad; untreated and 1 cellulose support pad; sodium carbonate | 10 | 225-9001 | |
| Benzidine | OSHA 65 | 2 Glass fibre filters; sulphuric acid | 10 | 225-9004 | |
| Bromine, chlorine | NIOSH 6011 | 1 25 mm PTFE pre-filter and polypropylene support; 1 25 mm specially cleaned silver membrane and polypropylene support in 25 mm cassette | 5 | 225-9006 | |
| Crotonaldehyde | OSHA 81 | 2 Glass fibre filters; 2,4-dinitrophenylhydrazine and phosphoric acid | 10 | 225-9019 § | |
| o-Dianisidine | OSHA 71 | 2 Glass fibre filters; sulphuric acid | 10 | 225-9004 | |
| 3,3-Dichlorobenzidine | OSHA 65 | 2 Glass fibre filters; sulphuric acid | 10 | 225-9004 | |
| Diisocyanates &(HDI;2,6-TDI;2,4-TDI) | ASTM D5836 Δ OSHA 42 | 1 Glass fibre filter and cellulose support; 1-(2-pyridyl) piperazine | 10 | 225-9013 § † | |
| Diisocyanates &(HDI;2,6-TDI;2,4-TDI) | OSHA 42 | 1 Glass fibre filter and cellulose support; 1-(2-pyridyl) piperazine | 10 | 225-9002 § ‡ | |
| Diphenylamine | OSHA 78 | 2 Glass fibre filters; sulphuric acid | 10 | 225-9004 | |
| Fluorides | OSHA ID-110 NIOSH 7902 ASTM D4765 | 1 MCE filter and cellulose pad; sodium carbonate | 10 | 225-9001 # | |
| Fluorides, particulate | NIOSH 7906 | 2 Nitrocellulose filters; 1 coated with sodium carbonate, 1 uncoated | 10 | 225-9031 | |
| Glutaraldehyde | OSHA 64 | 2 Glass fibre filters; 2,4-dinitrophenyl hydrazine and phosphoric acid | 10 | 225-9003 § | |
| Hexavalent Chromium in Chromium Plating Mist | MDHS 52/4 | 25mm Polyvinylidine Fluoride Filter; sodium hydroxide (filters only) | 24 | 225-9026 | |
| Hydrazine | OSHA 108 | 2 Glass fibre filters; sulphuric acid | 10 | 225-9012 | |
| Hydrofluoric acid | NIOSH 7906 | 2 Nitrocellulose filters; 1 coated with sodium carbonate, 1 uncoated | 10 | 225-9031 | |
| Hydrogen bromide | NIOSH 7907 | 2 Quartz filters; sulphuric acid; 1 coated with sodium carbonate, 1 uncoated | 10 | 225-9032 | |
| Hydrogen chloride | NIOSH 7907 | 2 Quartz filters; sulphuric acid; 1 coated with sodium carbonate, 1 uncoated | 10 | 225-9032 | |
| Hydrogen Peroxide | OSHA 1019 | 2 25 mm Quartz filters; titanium oxysulphate hydrate in 25 mm cassette | 10 | 225-9030 (OSHA 1019) • | |
| Hydrogen Peroxide | NON 57 | 2 25 mm Quartz filters; titanium oxysulphate hydrate in 25 mm cassette | 10 | 225-9030 (NON 57) • | |
| Isocyanates | ASTM ∑ | 1 PTFE filter, 1 Glass filter treated with MAMA (ISO-CHEK Sampling System) | 12 | 225-9022 ∑ | |
| Isocyanates | ASTM ∑ | 1 PTFE filter, 1 Glass filter treated with MAMA (ISO-CHEK Sampling System) | 36 | 225-9022A ∑ | |
| Isocyanates (HDI;2,6-TDI;2,4-TDI) | ASTM D5836 Δ | 1 Glass fibre filter and cellulose support; 1-(2-pyridyl) piperazine | 10 | 225-9013 § † | |
| Isocyanates (HDI;2,6-TDI;2,4-TDI) | OSHA 42 ‡ | 1 Glass fibre filter and cellulose support; 1-(2-pyridyl) piperazine | 36 | 225-9002 § ‡ | |
| Isocyanates (HDI, MDI, TDI, IPDI, HDI-BT, HDI-IC) | OR-OSHA 1010 | 1 Glass fibre filter; MAMA 13 mm preloaded in a 13 mm Swinnex holder | 5 | 225-9029 § ¶ | |
| Isocyanates, organic | MDHS 25/4 (UK) | 1 25 mm A/E Glass filter; methoxyphenyl piperazine (filters only) | 5 | Special Order § | |
| n-Isopropylaniline | OSHA 78 | 2 Glass fibre filters; sulphuric acid | 10 | 225-9004 | |
| Maleic anhydride | OSHA 86 | 2 Glass fibre filters; veratrylamine | 10 | 225-9021 § | |
| Maleic anhydride | For IFV | 1 25 mm Glass fibre filter; veratrylamine (filters only) | 10 | 225-9028 § | |
| Mercaptans (methyl-, ethyl-, n-butyl, and phenyl-) | NIOSH 2542 OSHA 26 | 1 Glass fibre filter; mercuric acetate | 10 | 225-9007 § | |
| 4,4′-Methylene bis (2-chloroaniline) (MOCA) | OSHA 71 | 2 Glass fibre filters; sulphuric acid | 10 | 225-9004 | |
| Methylene bisphenyl (MDI) | OSHA 47 | 1 Glass fibre filter and cellulose support; 1-(2-pyridyl) piperazine | 10 | 225-9013 § † | |
| Methylene bisphenyl (MDI) | OSHA 47 | 1 Glass fibre filter and cellulose support; 1-(2-pyridyl) piperazine | 36 | 225-9002 § ‡ | |
| 4,4′-Methylenedianiline | OSHA 57 Ω NIOSH 5029 | 2 Glass fibre filters; sulphuric acid | 10 | 225-9004 | |
| 1-Naphthylamine, 2-naphthylamine | OSHA 93 | 2 Glass fibre filters; sulphuric acid | 10 | 225-9004 | |
| Nitric acid | NIOSH 2017 | 2 Quartz filters; 1 coated with sodium carbonate, 1 uncoated | 10 | 225-9032 | |
| Nitrobenzene | NIOSH 2017 | 2 Glass fibre filters; sulphuric acid | 10 | 225-9004 ¥ | |
| Ozone | OSHA ID-214 | 2 Glass fibre filters; nitrite-impregnated | 10 | 225-9014 § | |
| Peracetic Acid | OSHA PV2321 | 1 Quartz filters (R-100); titanium oxysulphate hydrate (TiOSO4) preloaded in 25 mm 2-piece clear cassette | 10 | 225-9037 ♦ | |
| Phenylenediamine (o-, m-, p-) | OSHA 87 | 2 Glass fibre filters; sulphuric acid | 10 | 225-9004 | |
| Phosphine | OSHA 1003 | 1 Glass fibre filter; 1 polyester filter treated with mercuric chloride | 10 | 225-9018 § † | |
| Phosphoric acid | NIOSH 7908 | 1 Quartz filter | 10 | 225-9033 ♠ | |
| Phthalic anhydride | OSHA 90 | 2 Glass Fibre filters, veratrylamine | 10 | 225-9034 § | |
| Sulphur dioxide | NIOSH 6004 (modified) | 1 MCE pre-filter and support/1 cellulose filter and support; sodium carbonate | 10 | 225-9005 | |
| Sulphuric acid | NIOSH 7908 | 1 Quartz filter | 10 | 225-9033 ♠ | |
| 2,4-Toluendiamine | OSHA 65 | 2 Glass fibre filters; sulphuric acid | 10 | 225-9004 | |
| 2,6-Toluendiamine | OSHA 65 | 2 Glass fibre filters; sulphuric acid | 10 | 225-9004 | |
| o-Tolidine | OSHA 71 | 2 Glass fibre filters; sulphuric acid | 10 | 225-9004 | |
| o-Toluidine | NIOSH 2017 | 2 Glass fibre filters; sulphuric acid | 10 | 225-9004 ¥ | |
| Toluidine (o-, m-, p-) | OSHA 73 | 2 Glass fibre filters; sulphuric acid | 10 | 225-9004 | |
| 1,3,5-Triglycidyl isocyanurate (TGI) | OSHA PV2055 | 1 Glass fibre filter; hydrobromic acid | 10 | 225-9027 | |
| Valeraldehyde | OSHA 85 | 3 Glass fibre filters; 2,4-dinitrophenylhydrazine and phosphoric acid | 10 | 225-9020 § | |
| m-Xylenediamine (m-XDA, p-XDA) | OSHA 105 | 2 Glass fibre filters; sulphuric acid | 10 | 225-9004 |
No rows match your search.