CAS number
108-95-2
Also known as
Carbolic acid · Carbolic acid (phenol) · Hydroxybenzene · Phenic acid · Phenol (carbolic acid) · Phenol (cresols)

UK workplace exposure limits

LimitValueApplies to
8-hour TWA 2 ppm
8-hour TWA 7.8 mg/m³
15-minute STEL 4 ppm
15-minute STEL 16 mg/m³

Notations

  • Sk: can be absorbed through the skin

Sampling methods

MethodSamplingMedium AnalysisPart numbers
MDHS 72
VOCs by thermal desorption and GC
Method document (opens in a new tab)
Active (pump) Tenax TD tube (250mg) 226-357
MDHS 96
VOCs by solvent desorption and GC
Method document (opens in a new tab)
Active (pump) XAD-7 tube (100/50mg) GC-FID 226-95
MDHS 104
VOCs by thermal desorption and GC
Method document (opens in a new tab)
Active (pump) Tenax TD tube (250mg) 226-357
NIOSH 2546
Cresol (all isomers) & Phenol by GC-FID
Method document (opens in a new tab)
Active (pump) XAD-7 tube (100/50mg) GC-FID 226-95
NIOSH 2549
VOCs (screening) by thermal desorption and GC -MS
Method document (opens in a new tab)
Active (pump) Thermal desorption tube 226-330
NIOSH 3502
Phenol by GC-FID
Method document (opens in a new tab)
Active (pump) Fritted midget impinger 225-35-2
225-22
OSHA 32
Phenol & Cresol by HPLC/UV
Method document (opens in a new tab)
Active (pump) XAD-7 tube (100/50mg) HPLC-UV 226-95
EPA TO-8
Phenol and Methylphenols by HPLC
Method document (opens in a new tab)
Active (pump) Midget impinger HPLC-UV 225-36-1
225-22
EPA TO-17 Active (pump) TD, GC 226-350
226-347
224-26-02
224-26-CPC
EPA TO-17
Toxic Organic Compounds by thermal desorption and GC
Method document (opens in a new tab)
Active (pump) Thermal desorption tube 226-300
Non-agency
Phenol by Colorimetric analysis
Direct-reading Gastec detector tube 810-60
Non-agency
VOCs by solvent desorption and GC-FID
Method document (opens in a new tab)
Passive Passive sampler 575-001
575-002
Other Passive GC-FID 575-001
575-002

Methods and limits as published by their agencies and summarised by SKC; check the current method and the limit that applies to you before sampling.