o-Toluidine

CAS number
95-53-4
Also known as
1-Amino-2-methylbenzene · 2-Aminotoluene · 2-Methylaniline · o-Methylaniline · o-Toluidine (Amines, Aromatic) · ortho-Methylaniline · Orthotoluidine

UK workplace exposure limits

LimitValueApplies to
8-hour TWA 0.1 ppm
8-hour TWA 0.5 mg/m³

Notations

  • Carc: carcinogen
  • Sk: can be absorbed through the skin

Sampling methods

MethodSamplingMedium AnalysisPart numbers
MDHS 75
Aromatic amines by HPLC
Method document (opens in a new tab)
Active (pump) IOM & glass fibre filter (requires coating) (or coated filter in preloaded cassette) with Tenax tube (30/15mg) HPLC 225-70A
225-58F
225-9004
226-35
MDHS 96
VOCs by solvent desorption and GC
Method document (opens in a new tab)
Active (pump) Silica gel tube (150/75mg) GC-FID 226-10
MDHS 104
VOCs by solvent desorption and GC
Method document (opens in a new tab)
Active (pump) Silica gel tube (150/75mg) 226-10
NIOSH 2002
Aromatic amines by GC-FID
Method document (opens in a new tab)
Active (pump) Silica gel tube (150/75mg) GC-FID or GC-NSD 226-10
NIOSH 2017
Aniline, o-Toluidine, & Nitrobenzene by GC-FID
Method document (opens in a new tab)
Active (pump) Coated glass fibre filter in preloaded cassette with silica gel tube (520/260mg) GC-FID 225-9004
226-15
225-1
OSHA 73
o-, m- and p-Toluidine by GC-ECD
Method document (opens in a new tab)
Active (pump) Two acid-treated glass fibre filters in preloaded cassette GC-ECD 225-9004
225-1
Non-agency
o-Toluidine by Colorimetric analysis
Direct-reading Gastec detector tube 810-181

Methods and limits as published by their agencies and summarised by SKC; check the current method and the limit that applies to you before sampling.

Source: SKC Ltd (UK), Hazard Search, used with SKC's permission (opens in a new tab); SKC Inc. (USA), Sampling Guides, used with SKC's permission (opens in a new tab)