Hazard search

Maleic anhydride

CAS number
108-31-6
Also known as
2,5-Furandione · Dihydro-2,5-dioxofuran

UK workplace exposure limits

LimitValueApplies to
8-hour TWA 1 mg/m³
15-minute STEL 3 mg/m³

Notations

  • Sen: can cause sensitisation

Sampling methods

MethodSamplingMedium AnalysisPart numbers
MDHS 72
VOCs by thermal desorption and GC
Method document (opens in a new tab)
Active (pump) Tenax thermal desorption tube (250mg) TD, GC 226-357
MDHS 104
VOCs by thermal desorption and GC
Method document (opens in a new tab)
Active (pump) Tenax TD tube (250mg) 226-357
NIOSH 3512
Maleic anhydride by HPLC/UV
Method document (opens in a new tab)
Active (pump) Fritted impinger HPLC-UV 225-36-2
225-22
OSHA 86
Maleic anhydride by HPLC/UV
Method document (opens in a new tab)
Active (pump) Coated glass fibre filter in cassette HPLC-UV 225-9021
225-1
EPA TO-17 Active (pump) TD, GC 226-350
226-347
224-26-02
224-26-CPC
EPA TO-17
VOCs by thermal desorption and GC
Method document (opens in a new tab)
Active (pump) Two Thermal Desorption tubes
EPA TO-17
Toxic Organic Compounds by thermal desorption and GC
Method document (opens in a new tab)
Passive Passive sampler
Non-agency
Maleic anhydride by HPLC/UV (as per OSHA 86)
Active (pump) IOM & coated filter 225-70A
225-9028
Non-agency
Maleic anhydride by Colorimetric analysis
Direct-reading Gastec detector tube 810-81

Methods and limits as published by their agencies and summarised by SKC; check the current method and the limit that applies to you before sampling.

Source: SKC Ltd (UK), Hazard Search, used with SKC's permission (opens in a new tab); SKC Inc. (USA), Sampling Guides, used with SKC's permission (opens in a new tab)