Hexamethylene diisocyanate

CAS number
822-06-0
Also known as
1,6-Hexamethylene diisocyanate · HDI · HDI (see hexamethylene diisocyanate) · Hexamethylene diisocyanate (gaseous) · Hexamethylene diisocyanate (HMD) · Hexamethylene diisocyanate (isocyanates) · Hexamethylene diisocyanate (monomeric aerosol) · Hexamethylene diisocyanate (monomeric gaseous) · Hexamethylene diisocyanate (oligomeric aerosol)

UK workplace exposure limits

LimitValueApplies to
8-hour TWA 0.02 mg/m³
15-minute STEL 0.07 mg/m³

Notations

  • Sen: can cause sensitisation

Sampling methods

MethodSamplingMedium AnalysisPart numbers
MDHS 25/4
Organic Isocyanates in air (aerosols) by HPLC -EC
Method document (opens in a new tab)
Active (pump) Midget impinger & coated glass fibre filter 225-36-4
225-22
MDHS 25/4
Organic Isocyanates in air (aerosols per Appendix 2) by HPLC -EC
Method document (opens in a new tab)
Active (pump) Stainless Steel IOM with coated filter(s) 225-79A
MDHS 25/4
Organic Isocyanates in air (vapours only) by HPLC -EC
Method document (opens in a new tab)
Active (pump) Stainless Steel IOM with coated glass fibre filter 225-79A
NIOSH 5521
Isocyanates (monomeric) by HPLC -ECD/UV
Method document (opens in a new tab)
Active (pump) Midget impinger HPLC-ELCHM & HPLC-UV 225-36-1
225-22
NIOSH 5522
Isocyanates by HPLC -FD/ECD
Method document (opens in a new tab)
Active (pump) Midget impinger HPLC-FD 225-36-1
225-22
NIOSH 5525
Isocyanates (total) by HPLC/UV
Method document (opens in a new tab)
Active (pump) Stainless steel IOM + GF filter 225-76A
225-702
OSHA 5002
Organic Vapour Sampling Group 3-diisocyanates- by UHPLC-FD
Method document (opens in a new tab)
Active (pump) Glass fibre filter & support pad in open-face cassette HPLC-UV or HPLC-FD 225-9002
225-9013
225-1
OSHA 5002
Organic Vapour Sampling Group 3 by UHPLC-FLR
Method document (opens in a new tab)
Active (pump) Open-face cassette with Glass Fibre Filter & support pad (page 2 of method) 225-3250
225-7
225-27
ASTM D6561
HDI (aerosol) by HPLC/UV
Method document (opens in a new tab)
Active (pump) PTFE and coated glass fibre filter in cassette HPLC-UV 225-9022
225-9023
225-1
ASTM D6562
HDI (gaseous) by HPLC/UV
Method document (opens in a new tab)
Active (pump) PTFE and coated glass fibre filter in cassette HPLC-UV or HPLC-FD 225-9022
225-9023
225-1