Hazard search

Glutaraldehyde

CAS number
111-30-8
Also known as
1,5-Pentanedial · Glutaric dialdehyde

UK workplace exposure limits

LimitValueApplies to
8-hour TWA 0.05 ppm
8-hour TWA 0.2 mg/m³
15-minute STEL 0.05 ppm
15-minute STEL 0.2 mg/m³

Notations

  • Sen: can cause sensitisation

Sampling methods

MethodSamplingMedium AnalysisPart numbers
MDHS 93
Glutaraldehyde by HPLC
Method document (opens in a new tab)
Active (pump) Coated glass fibre filters in 37mm cassette 225-9003
225-1
MDHS 102
Aldehydes by HPLC
Method document (opens in a new tab)
Active (pump) Coated Glass fibre filters OR coated silica gel tube HPLC 225-9003
226-119
226-120
MDHS 102
Aldehydes by HPLC
Method document (opens in a new tab)
Passive Passive sampler HPLC 500-100
NIOSH 2531
Glutaraldehyde by GC-FID
Method document (opens in a new tab)
Active (pump) Coated XAD-2 tube (120/60mg) GC-FID 226-118
NIOSH 2532 Active (pump) HPLC-UV 226-119
NIOSH 2532
Glutaraldehyde by HPLC/UV
Method document (opens in a new tab)
Active (pump) Coated silica gel tube (300/150mg) 225-119
OSHA 64
Glutaraldehyde by HPLC/UV
Method document (opens in a new tab)
Active (pump) Coated glass fibre filters in 37mm cassette HPLC-UV 225-9003
225-1
225-9019
Non-agency 43 Active (pump) GC-FID 226-10
Other Passive HPLC-UV 500-100

Methods and limits as published by their agencies and summarised by SKC; check the current method and the limit that applies to you before sampling.