Hazard search

Toluene

CAS number
108-88-3
Also known as
Methyl benzene · Phenylmethane · Toluene (Hydrocarbons, Aromatic) · Toluene (see online Passive Sampling Guide) · Toluol

UK workplace exposure limits

LimitValueApplies to
8-hour TWA 50 ppm
8-hour TWA 191 mg/m³
15-minute STEL 100 ppm
15-minute STEL 384 mg/m³

Notations

  • Sk: can be absorbed through the skin

Sampling methods

MethodSamplingMedium AnalysisPart numbers
MDHS 72
VOCs by thermal desorption and GC
Method document (opens in a new tab)
Active (pump) Tenax (250mg) or Chromosorb 106 (300mg) thermal desorption tube TD, GC 226-357
226-358
MDHS 80 Active (pump) GC-ECD 226-357
226-358
MDHS 80
VOCs by thermal desorption and GC
Method document (opens in a new tab)
Passive Anasorb GCB1 diffusive thermal desorption tube (500mg) with diffusive end caps 226-521
226-525
MDHS 88
VOCs by solvent desorption and GC
Method document (opens in a new tab)
Passive Passive sampler GC-FID 575-001
575-002
MDHS 96
VOCs by solvent desorption and GC
Method document (opens in a new tab)
Active (pump) Charcoal tube (100/50mg) GC-FID 226-01
MDHS 104
VOCs by solvent desorption and GC
Method document (opens in a new tab)
Active (pump) Charcoal tube (100/50mg) 226-01
MDHS 104
VOCs by thermal desorption and GC
Method document (opens in a new tab)
Active (pump) Tenax TA Tube (250 mg) or Chromosorb 106 Tube (300 mg) 226-357
226-358
MDHS 104
VOCs by thermal desorption and GC
Method document (opens in a new tab)
Passive Anasorb GCB1 (400mg) thermal desorption tube 226-521
NIOSH 1501
Hydrocarbons (aromatic) by GC-FID
Method document (opens in a new tab)
Active (pump) Charcoal tube (100/50mg) GC-FID 226-01
NIOSH 2549
VOCs (screening) by thermal desorption and GC -MS
Method document (opens in a new tab)
Active (pump) Thermal desorption tube 226-330
NIOSH 4000
Toluene by GC-FID
Method document (opens in a new tab)
Passive Passive sampler 575-001
OSHA 111
Toluene by GC-FID
Method document (opens in a new tab)
Active (pump) Charcoal sorbent tube (100/50mg) OR Anasorb 747 tube (140/70mg) GC-FID 226-01
226-81A
OSHA 111
Toluene by GC-FID
Method document (opens in a new tab)
Passive Passive sampler GC-FID 575-002
OSHA 5000
Organic Vapour Sampling Group 1 by GC-FID
Method document (opens in a new tab)
Active (pump) Anasorb CSC sorbent tube 226-01
ASTM D 5466 GC-MS
EPA TO-17 Active (pump) TD, GC 226-350
226-347
224-26-02
224-26-CPC
EPA TO-17
VOCs by thermal desorption and GC
Method document (opens in a new tab)
Active (pump) Two Thermal Desorption tubes
EPA TO-17
Toxic Organic Compounds by thermal desorption and GC
Method document (opens in a new tab)
Passive Passive sampler
Non-agency
Toluene by Colorimetric analysis
Direct-reading Gastec detector tube 810-122
810-122L
810-161
Non-agency
VOCs by solvent extraction and GC
Method document (opens in a new tab)
Passive Anasorb CSC (500mg) passive sampler 690-105
Non-agency
VOCs by thermal desorption and GC
Method document (opens in a new tab)
Passive Anasorb GBC1 (370mg) or Chromosorb 106 (285 mg) or Tenax TA (265 mg) passive sampler 690-101
690-103
690-104
Non-agency
VOCs by thermal desorption and GC
Method document (opens in a new tab)
Passive Anasorb GBC1 (370mg) or Chromosorb 106 (285 mg) or Tenax TA (265 mg) passive sampler with rate reducer 690-101
690-103
690-104
690-300
Non-agency
Toluene by Colorimetric analysis
Passive Gastec Dosi-tube 810-122DL
Other Passive GC-FID 575-001
Other Passive GC-FID 575-002
Other Passive TD, GC 690-101
690-103
690-104
690-300
Other Passive GC-FID 690-105
Other Passive DR 810-122DL
Other Internal Passive TD, GC 690-101
690-103
690-104
690-300
Other Internal Passive GC-FID 690-105

Methods and limits as published by their agencies and summarised by SKC; check the current method and the limit that applies to you before sampling.