Hazard search

Iron oxide

CAS number
1309-37-1
Also known as
Ferric oxide · Iron oxide (Elements by ICP HNO3 Digestion) · Iron oxide (fume) (as Fe) · Iron oxide fume · Iron oxide red · Iron(III) oxide · Red iron oxide · Rouge (inhalable) · Rouge (particulates, respirable) · Rouge (particulates, total) · Rouge (respirable) · Rouge (total inhalable) · Rouge (total respirable)

UK workplace exposure limits

LimitValueApplies to
8-hour TWA 5 mg/m³ Iron oxide
15-minute STEL 10 mg/m³ Iron oxide
8-hour TWA 10 mg/m³ Rouge (inhalable)
8-hour TWA 4 mg/m³ Rouge (respirable)

Sampling methods

MethodSamplingMedium AnalysisPart numbers
MDHS 14/4
General inhalable or respirable dusts by gravimetric analysis (respirable)
Method document (opens in a new tab)
Active (pump) IOM & foam (or cyclone) with GF filter GR 225-70A
225-772
225-69
225-58F
MDHS 14/4
General inhalable or respirable dusts by gravimetric analysis (inhalable)
Method document (opens in a new tab)
Active (pump) IOM with glass fibre filter GR 225-70A
225-58F
MDHS 91/2
Metals & metalloids by XRF
Method document (opens in a new tab)
Active (pump) IOM with 0.8µm MCE filter XRF 225-70A
225-19
225-1930
NIOSH 0500
Particulates Not Otherwise Regulated, Total GR
Method document (opens in a new tab)
Active (pump) Filter Cassette GR 225-5-37-P
225-2LF
225-1
NIOSH 0600
Particulates Not Otherwise Regulated, Respirable GR
Method document (opens in a new tab)
Active (pump) Filter Cassette GR 225-01-02
225-5-37-P
225-3LF
225-1
225-8208A
225-3851-PW
NIOSH 7303
Elements by ICP (Hot block/HCl/HNO3 Digestion)
Method document (opens in a new tab)
Active (pump) 0.8µm MCE filter in cassette ICP-AES 225-3-01
225-1
OSHA ID 121 Active (pump) AA or AES 225-3-01
225-1
OSHA ID 125G Active (pump) ICP-AES 225-3-01
225-3100
225-1
OSHA ID-121
Metal & metalloid particulates by AAS
Method document (opens in a new tab)
Active (pump) 0.8µm MCE filter in cassette 225-3-01
225-1
OSHA ID-125G
Metals & metalloid particulates by ICP
Method document (opens in a new tab)
Active (pump) 0.8µm MCE filter in cassette 225-3-01
225-3100
225-1
ISO 10882-1: 2011
Welding fumes by gravimetric or chemical analysis
Method document (opens in a new tab)
Active (pump) Headset & minisampler with 13mm MCE filter 225-6200
225-6201
225-6202
225-8050

Methods and limits as published by their agencies and summarised by SKC; check the current method and the limit that applies to you before sampling.

Source: SKC Ltd (UK), Hazard Search, used with SKC's permission (opens in a new tab); SKC Inc. (USA), Sampling Guides, used with SKC's permission (opens in a new tab)