Hazard search

Chromium (VI) compounds (as Cr)

CAS number
No CAS number
Also known as
Ammonium chromate (dichromate) · Barium chromate · Chromium [VI] chloride · Hexavalent chromium · Lead Chromate · Molybdenum orange · Potassium chromate (dichromate) · Zinc chromate (hydroxides)

UK workplace exposure limits

LimitValueApplies to
8-hour TWA 0.01 mg/m³

Notations

  • BMGV: a biological monitoring guidance value exists
  • Carc: carcinogen
  • Sen: can cause sensitisation

Sampling methods

MethodSamplingMedium AnalysisPart numbers
MDHS 52/4
Hexavalent Chromium by Colorimetry (not suitable for measurement of personal exposure)
Method document (opens in a new tab)
Active (pump) IOM Sampler and treated PVDF filters 225-70A
225-9026
NIOSH 7300
Elements by ICP (Nitric/perchloric acid ashing)
Method document (opens in a new tab)
Active (pump) 0.8µm MCE filter in 37mm cassette 225-3-01
225-1
NIOSH 7600
Chromium (hexavalent) by VIS
Method document (opens in a new tab)
Active (pump) 5µm PVC filter in preloaded cassette 225-803
225-1
NIOSH 7604
Hexavalent Chromium by IC -CD (Withdrawn - for reference only)
Method document (opens in a new tab)
Active (pump) Filter Cassette 225-802
225-1
NIOSH 7605
Hexavalent chromium by IC
Method document (opens in a new tab)
Active (pump) 5µm PVC filter in preloaded cassette 225-803
225-1
NIOSH 7703
Hexavalent chromium by field-portable VIS
Method document (opens in a new tab)
Active (pump) 5µm PVC filter in 37mm cassette 225-802
225-1
OSHA ID-103
Hexavalent Chromium by DPP
Method document (opens in a new tab)
Active (pump) Filter Cassette 225-802
225-1
OSHA ID-215 V2
Hexavalent chromium by IC -UV
Method document (opens in a new tab)
Active (pump) 37mm, 5.0µm PVC filter in cassette 225-802
225-1
OSHA W4001
Hexavalent chromium by IC -UV
Method document (opens in a new tab)
Surface 5.0µm PVC filter or quartz fibre filter 225-5-37
225-1822
BS ISO 10882-1: 2011
Welding fumes by gravimetric or chemical analysis
Method document (opens in a new tab)
Active (pump) Headset & minisampler with 13mm MCE filter 225-6200
225-6201
225-6202
225-8050
BS ISO 16740:2005
Determination of hexavelent chromium in airborne particulate matter by IC
Method document (opens in a new tab)
Active (pump) IOM Sampler and PVC filters (or treated PVC for mist) 225-70A
225-5-25
225-9026

Methods and limits as published by their agencies and summarised by SKC; check the current method and the limit that applies to you before sampling.

Source: SKC Ltd (UK), Hazard Search, used with SKC's permission (opens in a new tab)