Hazard search

Chlorine

CAS number
7782-50-5
Also known as
Chlorine (prefiltered) · Cl

UK workplace exposure limits

LimitValueApplies to
15-minute STEL 0.5 ppm
15-minute STEL 1.5 mg/m³

Sampling methods

MethodSamplingMedium AnalysisPart numbers
NIOSH 6011
Chlorine by IC
Method document (opens in a new tab)
Active (pump) Silver membrane filter with PTFE prefilter in cassette IC 225-9006
225-1
OSHA ID 101 Active (pump) ISE 225-36-2
225-22
225-3-23
225-2901
225-17-21
OSHA ID-101
Chlorine by ISE
Method document (opens in a new tab)
Active (pump) Fritted midget impinger (with prefilter for particulates if required) 225-36-2
225-22
225-2708
225-2901
225-3
OSHA ID-126SGX
Chlorine & Chlorine dioxide by Titration
Method document (opens in a new tab)
Active (pump) Impinger with glass fibre prefilter in cassette 225-36-2
225-22
225-2708
225-2901
225-3
Non-agency
Chlorine by Colorimetric analysis
Direct-reading Gastec Detector tube 810-8
810-80
Non-agency
Chlorine by Colorimetric analysis
Passive Gastec Dosi-tube 810-8D
810-132D
Other Passive DR 810-132D
Other Passive DR 810-8D

Methods and limits as published by their agencies and summarised by SKC; check the current method and the limit that applies to you before sampling.

Source: SKC Ltd (UK), Hazard Search, used with SKC's permission (opens in a new tab); SKC Inc. (USA), Sampling Guides, used with SKC's permission (opens in a new tab)