Hazard search

Calcium carbonate (inhalable)

CAS number
1317-65-3
Also known as
Calcium carbonate · Calcium carbonate (particulates, respirable) · Calcium carbonate (particulates, total) · Calcium carbonate (respirable) · Calcium carbonate (see Particulates Not Otherwise Regulated, total and respirable) · Calcium monocarbonate · Limestone · Limestone (inhalable dust) · Limestone (particulates, total) · Limestone (respirable dust) · Limestone (see calcium carbonate) · Limestone (see Particulates Not Otherwise Regulated, total and respirable) · Marble · Marble (particulates, respirable) · Marble (particulates, total) · Marble (see Particulates Not Otherwise Regulated, total and respirable) · Marble (total inhalable) · Marble (total respirable)

UK workplace exposure limits

LimitValueApplies to
8-hour TWA 10 mg/m³ Calcium carbonate (inhalable)
8-hour TWA 4 mg/m³ Calcium carbonate (respirable)

Sampling methods

MethodSamplingMedium AnalysisPart numbers
MDHS 14/4
General inhalable or respirable dusts by gravimetric analysis (total inhalable)
Method document (opens in a new tab)
Active (pump) IOM & foam (or cyclone) with GF filter GR 225-70A
225-58F
225-772
225-69
MDHS 14/4
General inhalable or respirable dusts by gravimetric analysis (total inhalable)
Method document (opens in a new tab)
Active (pump) IOM with GF filter GR 225-70A
225-58F
NIOSH 500
Particulates not otherwise regulated (total inhalable) by Gravimetric analysis
Method document (opens in a new tab)
Active (pump) 37mm, 5µm PVC filter in cassette GR 225-5-37-P
225-2LF
225-1
NIOSH 0600
Particulates not otherwise regulated (respirable) by Gravimetric analysis
Method document (opens in a new tab)
Active (pump) Cyclone & 5µm PVC filter in cassette GR 225-01-02
225-5-37-P
225-3LF
225-1
225-8208A
225-3851-PW
NIOSH 0600
Particulates Not Otherwise Regulated, Respirable GR
Method document (opens in a new tab)
Active (pump) Filter Cassette 225-5-37-P
225-2LF
225-1
NIOSH 7020
Calcium & compounds by AAS
Method document (opens in a new tab)
Active (pump) 0.8µm MCE filter in cassette 225-3-01
225-1
OSHA ID 121 Active (pump) AA or AES 225-3-01
225-1
OSHA ID-121
Metal & metalloid particulates by AAS
Method document (opens in a new tab)
Active (pump) 0.8µm MCE filter in cassette 225-3-01
225-1
BS ISO 15202-1: 2020
Determination of metals and metalloids in airborne particulate matter by ICP
Active (pump) IOM with 0.8µm MCE filter 225-70A
225-1930
BS ISO 15202-1: 2020
Determination of metals and metalloids in airborne particulate matter by ICP
Active (pump) IOM with 0.8µm MCE filter and foam 225-70A
225-1930
225-772
Other

Methods and limits as published by their agencies and summarised by SKC; check the current method and the limit that applies to you before sampling.

Source: SKC Ltd (UK), Hazard Search, used with SKC's permission (opens in a new tab); SKC Inc. (USA), Sampling Guides, used with SKC's permission (opens in a new tab)