Hazard search

Arsenic and arsenic compounds except arsine (as As)

CAS number
No CAS number
Also known as
As, sodium arsenite and arsenic trichloride, arsenic pentoxide and arsenates (e.g. lead arsenate and calcium arsenate)

UK workplace exposure limits

LimitValueApplies to
8-hour TWA 0.1 mg/m³

Notations

  • Carc: carcinogen

Sampling methods

MethodSamplingMedium AnalysisPart numbers
MDHS 91/2
Metals & metalloids by XRF
Method document (opens in a new tab)
Active (pump) IOM with 0.8µm MCE filter 225-70A
225-1930
NIOSH 502
organo-Arsenic by IC
Method document (opens in a new tab)
Active (pump) 1µm PTFE filter in cassette 225-17-01
225-3LF
225-1
NIOSH 7900
Arsenic & compounds (except AsH3 & As2O3) by AAS
Method document (opens in a new tab)
Active (pump) 0.8µm MCE filter in cassette (or Solu-CAP cassette) 225-3-01
225-8517
OSHA 1006
Arsenic, Cadmium, Cobalt, Copper, Lead & Nickel by ICP -MS
Method document (opens in a new tab)
Active (pump) 0.8µm MCE filter with coated back-up pad in cassette 225-9001
BS ISO 15202-1: 2020
Determination of metals and metalloids in airborne particulate matter by ICP
Active (pump) IOM with 0.8µm MCE filter 225-70A
225-1930

Methods and limits as published by their agencies and summarised by SKC; check the current method and the limit that applies to you before sampling.

Source: SKC Ltd (UK), Hazard Search, used with SKC's permission (opens in a new tab)