Thermal Mass Flow Meters

Thermal mass flow meters for gases, measuring mass flow directly by heat transfer with no pressure or temperature correction. Compact aluminium or 316 stainless steel transducers with analog and digital outputs, for flow ranges from 5 smL/min to 1000 sL/min N2 — from Aalborg Instruments and ANALYT-MTC.

All models

4 models
  • GFM

    Compact thermal gas mass flow meter with tiltable LCD; aluminium or stainless, analog output.

    ±1% FS · to 1000 sL/min

    ANALYT-MTC
    Details →
  • XFM

    Digital thermal gas meter storing 10 gas calibrations, with totalizer, alarms and RS-232/485.

    ±1% FS · 5 smL–1000 sL/min

    Aalborg
    Details →
  • TIO Accessory Totalizer Input/Output

    Add-on module for GFM/GFC adding analog and digital I/O, a graphic totalizer display and alarms.

    12-bit · RS-232/485

    Aalborg
    Details →
  • ZFM digital mass flow meter

    Digital thermal gas meter with field-selectable gas type and range via free configuration software.

    ±(0.5% RD + 0.2% FS)

    Aalborg
    Details →

Which thermal mass flow meter should I choose for gas?

The three thermal gas meters here measure by heat transfer. The GFM is the compact one: a thermal gas mass flow meter with a tiltable LCD, in aluminium or stainless steel, with analog output and ranges to 1000 sL/min, ±1% FS on the GFM 17, 37 and 47. The XFM is a digital thermal gas meter that stores 10 gas calibrations and adds a totalizer, alarms and RS-232/485, from 5 smL–1000 sL/min. The ZFM digital mass flow meter lets you select gas type and range on site through free configuration software, with ±(0.5% RD + 0.2% FS).

What should I check for low flow gas measurement?

Check the range first: the series starts at 5 smL/min and the XFM covers 5 smL–1000 sL/min. Then check the line: the GFM 17, 37 and 47 take gas pressure to 70 barg, and the ZFM is rated to 68.9 bar(g). Gas temperature is 0°C to 50°C, and the GFM and XFM are calibrated at standard conditions of 1013 hPa and 21.11°C. Output is 0-5 Vdc and 4-20 mA.

Can I add a totalizer or alarms to a gas mass flow meter?

The TIO Accessory Totalizer Input/Output is an add-on module for the GFM and GFC. It adds analog and digital I/O, a graphic totalizer display and alarms, with 12 bit resolution and RS-232/485. To hold a flow at a setpoint instead of reading it, see the thermal mass flow controllers.

Questions about these products?

Our application engineers aim to reply within 3 business hours.

Ask an engineer