ZFM digital mass flow meter
Aalborg ZFM digital mass flow meter with high accuracy, in aluminum or stainless steel, for thermal gas flow measurement
The Aalborg ZFM is a compact digital mass flow meter that measures the flow rates of gases. Using thermal mass flow metering, it offers accuracy and high cost efficiency: ±(0.5% RD + 0.2% FS) based on actual calibration (at calibration temperature and pressure), with a repeatability of ±0.15% of full scale. Models are available in aluminum or stainless steel. It is part of the thermal mass flow meters range.
How do I change the gas type and flow range of a ZFM?
Running the free “ZFM Configuration Utility” software, the user can select different gas types and flow ranges on-site without disconnecting, within a few minutes.
How does a ZFM lower ownership costs?
These meters facilitate lower ownership costs by employing fewer units for multiple applications and saving on the cost of calibrations.
Which outputs, pressure and fittings does the ZFM digital thermal mass flow meter have?
- Outputs: linear 0-5 Vdc (3000 ohms min load impedance), linear 0-10 Vdc (5000 ohms min load impedance) and linear 4-20 mA (500 ohms maximum loop resistance).
- Gas pressure: max. 68.9 bar(g), optimal pressure 1.7 bar(g).
- Materials: aluminum models use anodized aluminum, brass, 316 stainless steel and Viton® O-rings; stainless steel models use 316 stainless steel and Viton® O-rings.
- Connections: 1/4″ compression fittings; optional 1/4″, 3/8”, 6 mm compression fittings or 1/4″ VCR.
Accessories include a power supply 230VAC Europe plug 24Vdc (PS-ZFM-230EU-4) and a USB to RS232 converter (35782).
| Parameter | Value |
|---|---|
| Accuracy | ±(0.5% RD + 0.2% FS) based on actual calibration (at calibration temperature and pressure). |
| Calibrations | Performed at standard conditions 101.4 kPa and 21.1 °C unless otherwise requested or stated. |
| Repeatability | ±0.15% of full scale. |
| Response Time | 2 secondes to within +/-2% of flow rate, over 25% to 100% full scale |
| Gas Temp. & ambient Temp. | Gas temp & Ambient temp (0°C to 50°C). |
| Output signals | Linear 0-5 Vdc (3000 ohms min load impedance) Linear 0-10 Vdc (5000 ohms min load impedance) Linear 4-20 mA (500 ohms maximum loop resistance) Maximum noise 10mV peak to peak (for 0-5 Vdc output) |
| Gas pressure | Max. 68.9 bar(g). Optimal pressure 1.7 bar(g). |
| Materials | Aluminum Models: Anodized aluminum, brass, 316 stainless steel, Viton® O-rings. Stainless Steel Models: 316 stainless steel, Viton® O-rings. Optional O-ring Materials: Buna-N® , EPR® (Ethylene Propylene), or Kalrez®. |
| Connections | 1/4″ compression fittings. Optional: 1/4″, 3/8”, 6 mm compression fittings or 1/4″ VCR. |
| Description | Part Number | ||
|---|---|---|---|
| ZFM power supply 230VAC Europe plug 24Vdc with DC jack power adapter. | PS-ZFM-230EU-4 | ||
| USB to RS232 converter. | 35782 | | |
| USB to 8x RS232 converter. | USB-RS232 | | |
| Universal Baseplate : A universal bench top stand commonly used with our flowmeters, controllers or rotameters. | 35780 | | |
| Pelicase for maximum safety during transport | 1200-000-110E | |
Questions about this product?
Our application engineers aim to reply within 3 business hours.