Hazard search
Vanadium pentoxide
- CAS number
- 1314-62-1
- Also known as
- Divanadium pentaoxide · Divanadium pentoxide · Vanadium fume (as V2O5) · Vanadium oxides · Vanadium pentoxide (V2O5) (see vanadium oxides) · Vanadium respirable dust (as V2O5) · Vanadium(V) oxide
UK workplace exposure limits
| Limit | Value | Applies to |
|---|---|---|
| 8-hour TWA | 0.05 mg/m³ |
Sampling methods
| Method | Sampling | Medium | Analysis | Part numbers |
|---|---|---|---|---|
| MDHS 91/2 Metals & metalloids by XRF Method document (opens in a new tab) | Active (pump) | IOM with 0.8µm MCE filter | XRF | 225-70A 225-19 225-1930 |
| NIOSH 7504 Vanadium oxides by XRD Method document (opens in a new tab) | Active (pump) | 5µm PVC filter with cyclone | XRD | 225-803 225-105 225-1 225-01-02 225-3851-PW |
| OSHA ID 125G | Active (pump) | ICP-AES | 225-3-01 225-3100 225-1 225-105 225-385 225-1939 | |
| OSHA ID-125G Metal & metalloid particulates in Workplace Atmospheres by ICP by AAS /AES Method document (opens in a new tab) | Active (pump) | Filter Cassette | 225-3-01 225-3100 225-8215 225-1 | |
| OSHA PV2121 Gravimetric Determination - GR Method document (opens in a new tab) | Active (pump) | Filter Cassette | 225-105 225-803 225-1 |
Methods and limits as published by their agencies and summarised by SKC; check the current method and the limit that applies to you before sampling.
Source: SKC Ltd (UK), Hazard Search, used with SKC's permission (opens in a new tab); SKC Inc. (USA), Sampling Guides, used with SKC's permission (opens in a new tab)