Hazard search

Vanadium pentoxide

CAS number
1314-62-1
Also known as
Divanadium pentaoxide · Divanadium pentoxide · Vanadium fume (as V2O5) · Vanadium oxides · Vanadium pentoxide (V2O5) (see vanadium oxides) · Vanadium respirable dust (as V2O5) · Vanadium(V) oxide

UK workplace exposure limits

LimitValueApplies to
8-hour TWA 0.05 mg/m³

Sampling methods

MethodSamplingMedium AnalysisPart numbers
MDHS 91/2
Metals & metalloids by XRF
Method document (opens in a new tab)
Active (pump) IOM with 0.8µm MCE filter XRF 225-70A
225-19
225-1930
NIOSH 7504
Vanadium oxides by XRD
Method document (opens in a new tab)
Active (pump) 5µm PVC filter with cyclone XRD 225-803
225-105
225-1
225-01-02
225-3851-PW
OSHA ID 125G Active (pump) ICP-AES 225-3-01
225-3100
225-1
225-105
225-385
225-1939
OSHA ID-125G
Metal & metalloid particulates in Workplace Atmospheres by ICP by AAS /AES
Method document (opens in a new tab)
Active (pump) Filter Cassette 225-3-01
225-3100
225-8215
225-1
OSHA PV2121
Gravimetric Determination - GR
Method document (opens in a new tab)
Active (pump) Filter Cassette 225-105
225-803
225-1

Methods and limits as published by their agencies and summarised by SKC; check the current method and the limit that applies to you before sampling.

Source: SKC Ltd (UK), Hazard Search, used with SKC's permission (opens in a new tab); SKC Inc. (USA), Sampling Guides, used with SKC's permission (opens in a new tab)