Hazard search

Pyridine

CAS number
110-86-1
Also known as
Azabenzene

UK workplace exposure limits

LimitValueApplies to
8-hour TWA 5 ppm
8-hour TWA 16 mg/m³
15-minute STEL 10 ppm
15-minute STEL 33 mg/m³

Sampling methods

MethodSamplingMedium AnalysisPart numbers
MDHS 72
VOCs by thermal desorption and GC
Method document (opens in a new tab)
Active (pump) Tenax thermal desorption tube (250mg) TD, GC 226-357
MDHS 88 Passive GC-FID 575-001
MDHS 88
VOCs by solvent desorption and GC
Method document (opens in a new tab)
Passive Passive sampler 575-002
MDHS 96
VOCs by solvent desorption and GC
Method document (opens in a new tab)
Active (pump) Charcoal tube (100/50mg) GC-FID 226-01
MDHS 104
VOCs by thermal desorption and GC
Method document (opens in a new tab)
Active (pump) Tenax TD tube (250mg) 226-357
NIOSH 1613
Pyridine by GC-FID
Method document (opens in a new tab)
Active (pump) Charcoal tube (100/50mg) GC-FID 226-01
OSHA PV2295
Pyridine by GC-FID
Method document (opens in a new tab)
Active (pump) Two XAD-7 tubes in series (100/50mg) GC-FID 226-95
EPA TO-17
VOCs by thermal desorption and GC
Method document (opens in a new tab)
Active (pump) Two Thermal Desorption tubes TD, GC 226-350
226-347
224-26-02
224-26-CPC
Non-agency
Pyridine by Colorimetric analysis
Direct-reading Gastec detector tube 810-182
Other Passive GC-FID 575-002

Methods and limits as published by their agencies and summarised by SKC; check the current method and the limit that applies to you before sampling.

Source: SKC Ltd (UK), Hazard Search, used with SKC's permission (opens in a new tab); SKC Inc. (USA), Sampling Guides, used with SKC's permission (opens in a new tab)