Hazard search

Methyl methacrylate

CAS number
80-62-6
Also known as
Methacrylic acid methyl ester · Methyl 2-methylpropenoate · Methyl methacrylate (MMA) · Methyl methacrylate (see online Passive Sampling Guide)

UK workplace exposure limits

LimitValueApplies to
8-hour TWA 50 ppm
8-hour TWA 208 mg/m³
15-minute STEL 100 ppm
15-minute STEL 416 mg/m³

Sampling methods

MethodSamplingMedium AnalysisPart numbers
MDHS 72
VOCs by thermal desorption and GC
Method document (opens in a new tab)
Active (pump) Tenax thermal desorption tube (250mg) TD, GC 226-357
MDHS 80 Active (pump) GC-ECD 226-115
MDHS 88
VOCs by solvent desorption and GC
Method document (opens in a new tab)
Passive Passive sampler GC-FID 575-002
MDHS 96
VOCs by solvent desorption and GC
Method document (opens in a new tab)
Active (pump) XAD-2 tube (400/200mg) GC-FID 226-30-06
MDHS 104
VOCs by thermal desorption and GC
Method document (opens in a new tab)
Active (pump) Tenax TD tube (250mg) 226-357
NIOSH 2537
Methyl & Ethyl methacrylate by GC-FID
Method document (opens in a new tab)
Active (pump) XAD-2 tube (400/200mg) GC-FID 226-30-06
OSHA 94
Methyl methacrylate by GC-FID
Method document (opens in a new tab)
Active (pump) Coated charcoal tube (110/55mg) GC-FID 226-73
EPA TO-17 Active (pump) TD, GC 226-350
226-347
224-26-02
224-26-CPC
EPA TO-17
VOCs by thermal desorption and GC
Method document (opens in a new tab)
Active (pump) Two Thermal Desorption tubes
EPA TO-17
Toxic Organic Compounds by thermal desorption and GC
Method document (opens in a new tab)
Passive Passive sampler
Non-agency
Methyl methacrylate by Colorimetric analysis
Direct-reading Gastec Detector Tube 810-149
Non-agency
VOCs by solvent extraction and GC
Method document (opens in a new tab)
Passive Anasorb CSC (500mg) passive sampler 690-105
Non-agency
VOCs by thermal desorption and GC
Method document (opens in a new tab)
Passive Anasorb GBC1 (370mg) or Chromosorb 106 (285 mg) passive sampler 690-101
690-103
Non-agency 54 Active (pump) GC-FID 226-81A
Other Passive GC-FID 575-002
Other Passive TD, GC 690-101
690-103
Other Passive GC-FID 690-105
Other Internal Passive TD, GC 690-101
690-103
Other Internal Passive GC-FID 690-105

Methods and limits as published by their agencies and summarised by SKC; check the current method and the limit that applies to you before sampling.

Source: SKC Ltd (UK), Hazard Search, used with SKC's permission (opens in a new tab); SKC Inc. (USA), Sampling Guides, used with SKC's permission (opens in a new tab)