Hazard search

m-Xylene

CAS number
108-38-3
Also known as
1,3-Dimethylbenzene · m-Xylene (Hydrocarbons, Aromatic) · m-Xylene (see online Passive Sampling Guide) · m-Xylol · meta-Xylene · meta-Xylol

UK workplace exposure limits

Our data hold no UK limit for this substance.

Sampling methods

MethodSamplingMedium AnalysisPart numbers
MDHS 72
VOCs by thermal desorption and GC
Method document (opens in a new tab)
Active (pump) Tenax (250mg) or Chromosorb 106 (300mg) thermal desorption tube 226-357
226-358
MDHS 88
VOCs by solvent desorption and GC
Method document (opens in a new tab)
Passive Passive sampler 575-001
575-002
MDHS 96
VOCs by solvent desorption and GC
Method document (opens in a new tab)
Active (pump) Charcoal tube (100/50mg) 226-01
NIOSH 1501
Hydrocarbons (aromatic) by GC-FID
Method document (opens in a new tab)
Active (pump) Charcoal tube (100/50mg) GC-FID 226-01
NIOSH 2549
VOCs (screening) by thermal desorption and GC -MS
Method document (opens in a new tab)
Active (pump) Thermal desorption tube 226-330
OSHA 1002
Xylenes by GC-FID
Method document (opens in a new tab)
Active (pump) Charcoal tube (100/50mg) GC-FID 226-01
OSHA 1002
Xylenes by GC-FID
Method document (opens in a new tab)
Passive Passive sampler GC-FID 575-002
ASTM D5466
VOCs by GC -MS
Method document (opens in a new tab)
Active (pump) Canister GC-MS
EPA TO-17 Active (pump) TD, GC 226-350
226-347
224-26-02
224-26-CPC
EPA TO-17
VOCs by thermal desorption and GC
Method document (opens in a new tab)
Active (pump) Two Thermal Desorption tubes
EPA TO-17
Toxic Organic Compounds by thermal desorption and GC
Method document (opens in a new tab)
Passive Passive sampler
Non-agency
Xylene by Colorimetric analysis
Direct-reading Gastec detector tube 810-123
810-123L
Non-agency
VOCs by solvent extraction and GC
Method document (opens in a new tab)
Passive Anasorb CSC (500mg) passive sampler 690-105
Non-agency
VOCs by thermal desorption and GC
Method document (opens in a new tab)
Passive Anasorb GBC1 (370mg) or Chromosorb 106 (285 mg) or Tenax TA (265 mg) passive sampler 690-101
690-103
690-104
Non-agency
VOCs by thermal desorption and GC
Method document (opens in a new tab)
Passive Anasorb GCB1 (370 mg) or Chromosorb 106 (285mg) or Tenax TA (265 mg) passive sampler with rate reducer 690-101
690-103
690-104
690-300
Non-agency
Xylene by Colorimetric analysis
Passive Gastec Dosi-tube 810-122DL
Other Passive GC-FID 575-001
575-002
Other Passive TD, GC 690-101
690-103
690-104
690-300
Other Passive GC-FID 690-105
Other Internal Passive TD, GC 690-101
690-103
690-104
690-300
Other Internal Passive GC-FID 690-105

Methods and limits as published by their agencies and summarised by SKC; check the current method and the limit that applies to you before sampling.