Hazard search
m-Xylene
- CAS number
- 108-38-3
- Also known as
- 1,3-Dimethylbenzene · m-Xylene (Hydrocarbons, Aromatic) · m-Xylene (see online Passive Sampling Guide) · m-Xylol · meta-Xylene · meta-Xylol
UK workplace exposure limits
Our data hold no UK limit for this substance.
Sampling methods
| Method | Sampling | Medium | Analysis | Part numbers |
|---|---|---|---|---|
| MDHS 72 VOCs by thermal desorption and GC Method document (opens in a new tab) | Active (pump) | Tenax (250mg) or Chromosorb 106 (300mg) thermal desorption tube | 226-357 226-358 | |
| MDHS 88 VOCs by solvent desorption and GC Method document (opens in a new tab) | Passive | Passive sampler | 575-001 575-002 | |
| MDHS 96 VOCs by solvent desorption and GC Method document (opens in a new tab) | Active (pump) | Charcoal tube (100/50mg) | 226-01 | |
| NIOSH 1501 Hydrocarbons (aromatic) by GC-FID Method document (opens in a new tab) | Active (pump) | Charcoal tube (100/50mg) | GC-FID | 226-01 |
| NIOSH 2549 VOCs (screening) by thermal desorption and GC -MS Method document (opens in a new tab) | Active (pump) | Thermal desorption tube | 226-330 | |
| OSHA 1002 Xylenes by GC-FID Method document (opens in a new tab) | Active (pump) | Charcoal tube (100/50mg) | GC-FID | 226-01 |
| OSHA 1002 Xylenes by GC-FID Method document (opens in a new tab) | Passive | Passive sampler | GC-FID | 575-002 |
| ASTM D5466 VOCs by GC -MS Method document (opens in a new tab) | Active (pump) | Canister | GC-MS | |
| EPA TO-17 | Active (pump) | TD, GC | 226-350 226-347 224-26-02 224-26-CPC | |
| EPA TO-17 VOCs by thermal desorption and GC Method document (opens in a new tab) | Active (pump) | Two Thermal Desorption tubes | ||
| EPA TO-17 Toxic Organic Compounds by thermal desorption and GC Method document (opens in a new tab) | Passive | Passive sampler | ||
| Non-agency Xylene by Colorimetric analysis | Direct-reading | Gastec detector tube | 810-123 810-123L | |
| Non-agency VOCs by solvent extraction and GC Method document (opens in a new tab) | Passive | Anasorb CSC (500mg) passive sampler | 690-105 | |
| Non-agency VOCs by thermal desorption and GC Method document (opens in a new tab) | Passive | Anasorb GBC1 (370mg) or Chromosorb 106 (285 mg) or Tenax TA (265 mg) passive sampler | 690-101 690-103 690-104 | |
| Non-agency VOCs by thermal desorption and GC Method document (opens in a new tab) | Passive | Anasorb GCB1 (370 mg) or Chromosorb 106 (285mg) or Tenax TA (265 mg) passive sampler with rate reducer | 690-101 690-103 690-104 690-300 | |
| Non-agency Xylene by Colorimetric analysis | Passive | Gastec Dosi-tube | 810-122DL | |
| Other | Passive | GC-FID | 575-001 575-002 | |
| Other | Passive | TD, GC | 690-101 690-103 690-104 690-300 | |
| Other | Passive | GC-FID | 690-105 | |
| Other Internal | Passive | TD, GC | 690-101 690-103 690-104 690-300 | |
| Other Internal | Passive | GC-FID | 690-105 |
Methods and limits as published by their agencies and summarised by SKC; check the current method and the limit that applies to you before sampling.
Source: SKC Ltd (UK), Hazard Search, used with SKC's permission (opens in a new tab); SKC Inc. (USA), Sampling Guides, used with SKC's permission (opens in a new tab)