Hazard search

Isopropanol

CAS number
67-63-0
Also known as
2-Propanol · Dimethylcarbinol · Isopropanol (isopropyl alcohol) · Isopropanol (isopropyl alcohol) (see online Passive Sampling Guide) · Isopropyl alcohol · Isopropyl alcohol (Alcohols I) · Isopropyl alcohol (isopropanol) · Isopropyl alcohol (isopropanol) (see online Passive Sampling Guide) · Propan-2-ol

UK workplace exposure limits

LimitValueApplies to
8-hour TWA 400 ppm
8-hour TWA 999 mg/m³
15-minute STEL 500 ppm
15-minute STEL 1250 mg/m³

Sampling methods

MethodSamplingMedium AnalysisPart numbers
MDHS 72
VOCs by thermal desorption and GC
Method document (opens in a new tab)
Active (pump) Chromosorb 106 tube (300mg) TD, GC 226-358
MDHS 88
VOCs by solvent desorption and GC
Method document (opens in a new tab)
Passive Passive sampler GC-FID 575-001
575-002
MDHS 96
VOCs by solvent desorption and GC
Method document (opens in a new tab)
Active (pump) Charcoal tube (100/50mg) GC-FID 226-01
MDHS 104
VOCs by solvent desorption and GC
Method document (opens in a new tab)
Active (pump) Charcoal tube (100/50mg) 226-01
MDHS 104
VOCs by thermal desorption and GC
Method document (opens in a new tab)
Active (pump) Chromosorb 106 tube (300mg) 226-358
NIOSH 1400
Alcohols by GC-FID
Method document (opens in a new tab)
Active (pump) Charcoal tube (100/50mg) GC-FID 226-01
NIOSH 2549
VOCs (screening) by thermal desorption and GC -MS
Method document (opens in a new tab)
Active (pump) Thermal desorption tube 226-330
OSHA 109
Isopropyl alcohol by GC-FID . Note: Withdrawn - Provided for Historical Reference Only
Method document (opens in a new tab)
Active (pump) Set of two Anasorb 747 tubes (400mg & 200mg) 226-82
OSHA 5001
Organic Vapor Sampling Group 2 by GC-FID
Method document (opens in a new tab)
Active (pump) Set of two Anasorb 747 tubes (400mg & 200mg) GC-FID 226-82
222-3L-1
EPA TO-17 Active (pump) TD, GC 226-350
226-347
224-26-02
224-26-CPC
EPA TO-17
VOCs by thermal desorption and GC
Method document (opens in a new tab)
Active (pump) Two Thermal Desorption tubes
EPA TO-17
Toxic Organic Compounds by thermal desorption and GC
Method document (opens in a new tab)
Passive Passive sampler
Non-agency
Isopropyl alcohol by Colorimetric analysis
Direct-reading Gastec detector tube 810-113
Non-agency
VOCs by solvent extraction and GC
Method document (opens in a new tab)
Passive Anasorb CSC (500mg) passive sampler 690-105
Non-agency
VOCs by thermal desorption and GC
Method document (opens in a new tab)
Passive Anasorb GBC1 (370mg) or Chromosorb 106 (285 mg) passive sampler 690-101
690-103
Other Passive GC-FID 575-001
575-002
Other Passive TD, GC 690-101
690-103
Other Passive GC-FID 690-105
Other Internal Passive TD, GC 690-101
690-103
Other Internal Passive GC-FID 690-105

Methods and limits as published by their agencies and summarised by SKC; check the current method and the limit that applies to you before sampling.

Source: SKC Ltd (UK), Hazard Search, used with SKC's permission (opens in a new tab); SKC Inc. (USA), Sampling Guides, used with SKC's permission (opens in a new tab)