Hazard search

Cyclohexanone

CAS number
108-94-1
Also known as
Cyclohexanone (Cyclohexyl ketone) · Cyclohexanone (Ketones I) · Cyclohexyl ketone · Ketohexamethylene · Pimelic ketone

UK workplace exposure limits

LimitValueApplies to
8-hour TWA 10 ppm
8-hour TWA 41 mg/m³
15-minute STEL 20 ppm
15-minute STEL 82 mg/m³

Notations

  • BMGV: a biological monitoring guidance value exists
  • Sk: can be absorbed through the skin

Sampling methods

MethodSamplingMedium AnalysisPart numbers
MDHS 72
VOCs by thermal desorption and GC
Method document (opens in a new tab)
Active (pump) Tenax TD tube (250mg) 226-357
MDHS 88
VOCs by solvent desorption and GC-FID
Method document (opens in a new tab)
Passive Anasorb CSC (350 mg) or Anasorb® 747 (500 mg) passive sampler GC-FID 575-001
575-002
MDHS 96
VOCs by solvent desorption and GC
Method document (opens in a new tab)
Active (pump) Charcoal tube (100/50mg) GC-FID 226-01
MDHS 104
VOCs by solvent desorption and GC
Method document (opens in a new tab)
Active (pump) Charcoal tube (100/50mg) 226-01
MDHS 104
VOCs by thermal desorption and GC
Method document (opens in a new tab)
Active (pump) Tenax TD tube (250mg) 226-357
NIOSH 1300
Ketones by GC-FID
Method document (opens in a new tab)
Active (pump) Charcoal tube (100/50mg) GC-FID 226-01
NIOSH 2027 GC-FID
NIOSH 2549
VOCs (screening) by thermal desorption and GC -MS
Method document (opens in a new tab)
Active (pump) Thermal desorption tube 226-330
NIOSH 2555
Ketones by GC-FID
Method document (opens in a new tab)
Active (pump) Anasorb CMS tube (150/75mg) GC-FID
OSHA 01
Cyclohexanone by GC-FID
Method document (opens in a new tab)
Active (pump) Chromosorb 106 tube (100/50mg) GC-FID 226-110
EPA TO-17 Active (pump) TD, GC 226-350
226-347
224-26-02
224-26-CPC
EPA TO-17
VOCs by thermal desorption and GC
Method document (opens in a new tab)
Active (pump) Two Thermal Desorption tubes
EPA TO-17
Toxic Organic Compounds by thermal desorption and GC
Method document (opens in a new tab)
Passive Passive sampler
Non-agency
Cyclohexanone by Colorimetric analysis
Direct-reading Gastec Detector Tube 810-154
810-91L
Non-agency
VOCs by solvent extraction and GC
Method document (opens in a new tab)
Passive Anasorb CSC (500mg) passive sampler 690-105
Non-agency
VOCs by thermal desorption and GC
Method document (opens in a new tab)
Passive Anasorb GBC1 (370mg) or Chromosorb 106 (285 mg) or Tenax TA (265 mg) passive sampler 690-101
690-103
690-104
Other Passive GC-FID 575-001
Other Passive GC-FID 575-002
Other Passive TD, GC 690-101
690-103
690-104
Other Passive GC-FID 690-105
Other Internal Passive TD, GC 690-101
690-103
690-104
Other Internal Passive GC-FID 690-105

Methods and limits as published by their agencies and summarised by SKC; check the current method and the limit that applies to you before sampling.

Source: SKC Ltd (UK), Hazard Search, used with SKC's permission (opens in a new tab); SKC Inc. (USA), Sampling Guides, used with SKC's permission (opens in a new tab)