Hazard search
Butyl acetate
- CAS number
- 123-86-4
- Also known as
- Butyl ethanoate · n-Butyl acetate · n-Butyl acetate (Esters I)
UK workplace exposure limits
| Limit | Value | Applies to |
|---|---|---|
| 8-hour TWA | 150 ppm | |
| 8-hour TWA | 724 mg/m³ | |
| 15-minute STEL | 200 ppm | |
| 15-minute STEL | 966 mg/m³ |
Sampling methods
| Method | Sampling | Medium | Analysis | Part numbers |
|---|---|---|---|---|
| MDHS 72 | Active (pump) | TD, GC | 226-358 | |
| MDHS 72 VOCs by thermal desorption and GC Method document (opens in a new tab) | Active (pump) | Charcoal tube (100/50mg) | 226-01 | |
| MDHS 80 | Active (pump) | GC-ECD | 226-358 | |
| MDHS 88 VOCs by solvent desorption and GC Method document (opens in a new tab) | Passive | Passive sampler | GC-FID | 575-001 575-002 |
| MDHS 96 VOCs by solvent desorption and GC Method document (opens in a new tab) | Active (pump) | Charcoal tube (100/50mg) | GC-FID | 226-01 |
| MDHS 104 VOCs by solvent desorption and GC Method document (opens in a new tab) | Active (pump) | Charcoal tube (100/50mg) | 226-01 | |
| MDHS 104 VOCs by thermal desorption and GC Method document (opens in a new tab) | Active (pump) | Tenax TA Tube (250 mg) or Chromosorb 106 Tube (300 mg) | 226-357 226-358 | |
| NIOSH 1450 Esters by GC-FID Method document (opens in a new tab) | Active (pump) | Charcoal tube (100/50mg) | GC-FID | 226-01 |
| NIOSH 2549 VOCs (screening) by thermal desorption and GC -MS Method document (opens in a new tab) | Active (pump) | Thermal desorption tube | 226-330 | |
| OSHA 1009 n-, Iso-, sec-, and tert-Butyl acetate by GC-FID Method document (opens in a new tab) | Active (pump) | Charcoal tube (100/50mg) | GC-FID | 226-01 |
| OSHA 1009 n-, Iso-, sec-, and tert-Butyl acetate by GC-FID Method document (opens in a new tab) | Passive | Passive sampler | GC-FID | 575-002 |
| OSHA 5000 Organic Vapour Sampling Group 1 by GC-FID Method document (opens in a new tab) | Active (pump) | Anasorb CSC sorbent tube | 226-01 | |
| EPA TO-17 | Active (pump) | TD, GC | 226-350 226-347 224-26-02 224-26-CPC | |
| EPA TO-17 VOCs by thermal desorption and GC Method document (opens in a new tab) | Active (pump) | Two Thermal Desorption tubes | ||
| EPA TO-17 Toxic Organic Compounds by thermal desorption and GC Method document (opens in a new tab) | Passive | Passive sampler | ||
| Non-agency Butyl acetate by Colorimetric analysis | Direct-reading | Gastec Detector tube | 810-142 810-142L | |
| Non-agency VOCs by solvent extraction and GC Method document (opens in a new tab) | Passive | Anasorb CSC (500mg) passive sampler | 690-105 | |
| Non-agency VOCs by thermal desorption and GC Method document (opens in a new tab) | Passive | Anasorb GBC1 (370mg) or Chromosorb 106 (285 mg) or Tenax TA (265 mg) passive sampler | 690-101 690-103 690-104 | |
| Other | Passive | GC-FID | 575-001 | |
| Other | Passive | GC-FID | 575-002 | |
| Other | Passive | TD, GC | 690-101 690-103 690-104 | |
| Other | Passive | GC-FID | 690-105 | |
| Other Internal | Passive | TD, GC | 690-101 690-103 690-104 | |
| Other Internal | Passive | GC-FID | 690-105 |
Methods and limits as published by their agencies and summarised by SKC; check the current method and the limit that applies to you before sampling.