- 1-Butanol · 1-Butyl alcohol · Butyl alcohol · n-Butanol · n-Butanol (alcohols combined) · n-Butanol (n-butyl alcohol) · n-Butyl alcohol · n-Butyl alcohol (1-butanol) · n-Butyl alcohol (alcohols combined) · n-Butyl alcohol (alcohols II)
UK workplace exposure limits
| Limit | Value | Applies to |
|---|---|---|
| 15-minute STEL | 50 ppm | |
| 15-minute STEL | 154 mg/m³ |
Notations
- Sk: can be absorbed through the skin
Sampling methods
| Method | Sampling | Medium | Analysis | Part numbers |
|---|---|---|---|---|
| MDHS 72 VOCs by thermal desorption and GC Method document (opens in a new tab) | Active (pump) | Tenax (250mg) or Chromosorb 106 (300mg) thermal desorption tube | TD, GC | 226-357 226-358 |
| MDHS 80 | Active (pump) | GC-ECD | 226-358 | |
| MDHS 80 VOCs by thermal desorption and GC Method document (opens in a new tab) | Passive | Chromosorb 106 tube (300mg) with diffusive end caps | 226-358 | |
| MDHS 88 VOCs by solvent desorption and GC Method document (opens in a new tab) | Passive | Passive sampler | GC-FID | 575-001 575-002 |
| MDHS 96 VOCs by solvent desorption and GC Method document (opens in a new tab) | Active (pump) | Charcoal tube (100/50mg) | GC-FID | 226-01 |
| MDHS 104 VOCs by solvent desorption and GC Method document (opens in a new tab) | Active (pump) | Charcoal tube (100/50mg) | 226-01 | |
| MDHS 104 VOCs by thermal desorption and GC Method document (opens in a new tab) | Active (pump) | Tenax TD tube (250mg) or Chromosorb 106 (300mg) tube | 226-357 226-358 | |
| NIOSH 1401 Alcohols by GC-FID Method document (opens in a new tab) | Active (pump) | Charcoal tube (100/50mg) | GC-FID | 226-01 |
| NIOSH 1405 Alcohols (combined) by GC-FID Method document (opens in a new tab) | Active (pump) | Charcoal tube (100/50mg) | GC-FID | 226-01 |
| NIOSH 2549 VOCs (screening) by thermal desorption and GC -MS Method document (opens in a new tab) | Active (pump) | Thermal desorption tube | 226-330 | |
| OSHA 5001 Organic Vapor Sampling Group 2 by GC-FID Method document (opens in a new tab) | Active (pump) | Set of two Anasorb 747 tubes (400mg & 200mg) | GC-FID | 226-82 222-3L-1 |
| EPA TO-17 VOCs by thermal desorption and GC Method document (opens in a new tab) | Active (pump) | Two Thermal Desorption tubes | TD, GC | 226-350 226-347 224-26-02 224-26-CPC |
| Non-agency 1-Butanol by Colorimetric analysis | Direct-reading | Gastec Detector tube | 810-114 | |
| Other | Passive | GC-FID | 575-001 | |
| Other | Passive | GC-FID | 575-002 |
Methods and limits as published by their agencies and summarised by SKC; check the current method and the limit that applies to you before sampling.