Hazard search

Beryllium

CAS number
7440-41-7
Also known as
Be · Beryllium & compounds · Beryllium & compounds (as Be) · Beryllium (Elements by Cellulosic Internal Capsule Sampler) · Beryllium (Elements by ICP Aqua Regia Ashing) · Beryllium (Elements by ICP HNO3 Digestion) · Beryllium (Elements by ICP HNO3/HClO4 Ashing) · Beryllium (Elements on Wipes) · Beryllium (ICP analysis of metal/metalloid particulates from solder operations) · Beryllium (in air by portable fluorometry)

UK workplace exposure limits

Our data hold no UK limit for this substance.

Notations

  • Carc: carcinogen

Sampling methods

MethodSamplingMedium AnalysisPart numbers
NIOSH 7102
Beryllium & compounds by AAS -GF
Method document (opens in a new tab)
Active (pump) 0.8µm MCE filter in cassette AA-GF 225-3-01
225-1
NIOSH 7300
Elements by ICP -AES (Nitric/perchloric acid ashing)
Method document (opens in a new tab)
Active (pump) 0.8µm MCE filter in cassette ICP-AES 225-3-01
225-1
225-8408
NIOSH 7301
Elements by ICP -AES (Aqua regia ashing)
Method document (opens in a new tab)
Active (pump) 0.8µm MCE filter or 5µm PVC filter in 37mm cassette ICP-AES 225-3-01
225-803
225-1
NIOSH 7303
Elements by ICP -AES (Hot block/HCl/HNO3 Digestion)
Method document (opens in a new tab)
Active (pump) 0.8µm MCE filter in 37mm cassette ICP-AES 225-3-01
225-1
NIOSH 7306
Elements by Cellulosic Internal Capsule Sampler ICP -AES
Method document (opens in a new tab)
Active (pump) Solu-CAP MCE Filters Preloaded in Cassettes and Cassette Holder ICP-AES 225-8517
225-1
NIOSH 7704
Beryllium by field-portable UV/VIS
Method document (opens in a new tab)
Active (pump) 0.8µm MCE filter in cassette P FLUOR UV/VIS 225-3-01
225-3100
225-1
NIOSH 9102
Elements on wipes by ICP -AES
Method document (opens in a new tab)
Surface Wipe ICP-AES 225-2414
225-2415
225-2415A
OSHA 1023
Beryllium and Compounds (as Be)by Inductively Coupled Plasma Optical Emission Spectrometry ICP -AES
Method document (opens in a new tab)
Active (pump) Filter Cassette ICP-AES 225-5
225-2LF
225-1
225-24
OSHA 1023
Beryllium and Compounds (as Be)by Inductively Coupled Plasma Optical Emission Spectrometry ICP -AES
Method document (opens in a new tab)
Surface Smear Tabs 225-24
OSHA ID 125G Active (pump) ICP-AES 225-3-01
225-3100
225-1
OSHA ID 206 Active (pump) ICP-AES 225-3-01
225-1
225-2413
OSHA ID-125G
Metals & metalloid particulates by ICP -AES
Method document (opens in a new tab)
Active (pump) 0.8µm MCE filter in cassette 225-3-01
225-3100
225-803
225-8215
225-1
OSHA ID-206
Metal & metalloid particulates from solder operations by ICP -AES
Method document (opens in a new tab)
Active (pump) 0.8µm MCE filter in 37mm cassette 225-3-01
225-1
BS ISO 15202-1: 2020
Determination of metals and metalloids in airborne particulate matter by ICP
Active (pump) IOM with 0.8µm MCE filter 225-70A
225-1930
Other Contact SKC Active (pump) AA 225-70A
225-1930

Methods and limits as published by their agencies and summarised by SKC; check the current method and the limit that applies to you before sampling.

Source: SKC Ltd (UK), Hazard Search, used with SKC's permission (opens in a new tab); SKC Inc. (USA), Sampling Guides, used with SKC's permission (opens in a new tab)