Hazard search

Barium sulphate (inhalable dust)

CAS number
7727-43-7
Also known as
Artificial barite · Barium sulfate · Barium sulfate (total dust) · Barium sulphate (respirable dust) · Blanc fixe

UK workplace exposure limits

LimitValueApplies to
8-hour TWA 10 mg/m³ Barium sulphate (inhalable dust)
8-hour TWA 4 mg/m³ Barium sulphate (respirable dust)

Sampling methods

MethodSamplingMedium AnalysisPart numbers
MDHS 14/4
General inhalable or respirable dusts by gravimetric analysis (respirable)
Method document (opens in a new tab)
Active (pump) IOM & foam (or cyclone) with GF filter GR 225-70A
225-772
225-69
225-58F
MDHS 14/4
General inhalable or respirable dusts by gravimetric analysis (total inhalable)
Method document (opens in a new tab)
Active (pump) IOM with GF filter GR 225-70A
225-58F
OSHA 204
Workplace Substances by XRF
Method document (opens in a new tab)
Active (pump) 0.8µm MCE filter in cassette with cyclone 225-3-01
225-105
225-1
OSHA ID 121 Active (pump) AA or AES 225-3-01
225-1
OSHA ID-121
Metal & metalloid particulates by AAS /AES
Method document (opens in a new tab)
Active (pump) 5µm PVC filter in cassette 225-802
225-1

Methods and limits as published by their agencies and summarised by SKC; check the current method and the limit that applies to you before sampling.