Hazard search

Welding fumes

CAS number
No CAS number
Also known as
Welding fumes (total particulate)

UK workplace exposure limits

Our data hold no UK limit for this substance.

Sampling methods

MethodSamplingMedium AnalysisPart numbers
MDHS 91/2
Metals & metalloids by XRF
Method document (opens in a new tab)
Active (pump) IOM with 0.8µm MCE filter 225-70A
225-19
OSHA ID 125G Active (pump) ICP-AES 225-3-01
225-3100
225-1
OSHA ID-125G
Metals & metalloid particulates by ICP
Method document (opens in a new tab)
Active (pump) 0.8µm MCE filter in cassette 225-3-01
225-3100
225-1
ISO 10882-1: 2011
Welding fumes by gravimetric or chemical analysis
Method document (opens in a new tab)
Active (pump) Headset & minisampler with 13mm MCE filter 225-6200
225-6201
225-6202
225-8050

Methods and limits as published by their agencies and summarised by SKC; check the current method and the limit that applies to you before sampling.

Source: SKC Ltd (UK), Hazard Search, used with SKC's permission (opens in a new tab); SKC Inc. (USA), Sampling Guides, used with SKC's permission (opens in a new tab)