Hazard search

Trichloroethylene

CAS number
79-01-6
Also known as
1,1,2-Trichloroethene · 1,1,2-Trichloroethylene · Acetylene trichloride · Ethylene trichloride · Trichloroethene · Trichloroethylene (hydrocarbons, halogenated) · Trichloroethylene (see online Passive Sampling Guide) · Trichloroethylene by portable GC

UK workplace exposure limits

LimitValueApplies to
8-hour TWA 100 ppm
8-hour TWA 550 mg/m³
15-minute STEL 150 ppm
15-minute STEL 820 mg/m³

Notations

  • Carc: carcinogen
  • Sk: can be absorbed through the skin

Sampling methods

MethodSamplingMedium AnalysisPart numbers
MDHS 72
VOCs by thermal desorption and GC
Method document (opens in a new tab)
Active (pump) Tenax (250mg) or Chromosorb 106 (300mg) thermal desorption tube TD, GC 226-357
226-358
MDHS 80 Active (pump) TD, GC 226-357
MDHS 88
VOCs by solvent desorption and GC
Method document (opens in a new tab)
Passive Passive sampler GC-FID 575-001
575-002
MDHS 96
VOCs by solvent desorption & GC
Method document (opens in a new tab)
Active (pump) Charcoal tube (100/50mg) GC-FID 226-01
MDHS 96
VOCs by solvent desorption and GC
Method document (opens in a new tab)
Active (pump) Charcoal tube (100/50mg) 226-01
MDHS 104
VOCs by thermal desorption and GC
Method document (opens in a new tab)
Active (pump) Tenax (250mg) or Chromosorb 106 (300mg) thermal desorption tube 226-357
226-358
MDHS 104
VOCs by solvent or thermal desorption and GC
Method document (opens in a new tab)
Active (pump) Tenax TD tube (250mg) 226-357
NIOSH 1003
Hydrocarbons (halogenated) by GC-FID
Method document (opens in a new tab)
Active (pump) Charcoal tube (100/50mg) GC-FID 226-01
NIOSH 1022
Trichloroethylene by GC-FID
Method document (opens in a new tab)
Active (pump) Charcoal tube (100/50mg) GC-FID 226-01
NIOSH 3701
Trichloroethlyene by portable GC -PID
Method document (opens in a new tab)
Active (pump) Sample bag P GC-PID 232-01
OSHA 1001
Tetrachloroethylene & Trichloroethylene by GC-FID
Method document (opens in a new tab)
Active (pump) Charcoal tube (100/50mg) GC-FID 226-01
OSHA 1001
Tetrachloroethylene & Trichloroethylene by GC-FID
Method document (opens in a new tab)
Passive Passive sampler GC-FID 575-002
OSHA 5000
Organic Vapour Sampling Group 1 by GC-FID
Method document (opens in a new tab)
Active (pump) Anasorb CSC sorbent tube 226-01
ASTM D 5466 GC-MS
EPA TO-17 Active (pump) TD, GC 226-350
226-347
224-26-02
224-26-CPC
EPA TO-17
VOCs by thermal desorption and GC
Method document (opens in a new tab)
Active (pump) Two Thermal Desorption tubes
EPA TO-17
Toxic Organic Compounds by thermal desorption and GC
Method document (opens in a new tab)
Passive Passive sampler
Non-agency
VOCs by solvent extraction and GC
Method document (opens in a new tab)
Passive Anasorb CSC (500mg) passive sampler 690-105
Non-agency
VOCs by solvent extraction and GC
Method document (opens in a new tab)
Passive Anasorb CSC (500mg) passive sampler with rate reducer 690-105
690-300
Non-agency
VOCs by thermal desorption and GC
Method document (opens in a new tab)
Passive Anasorb GBC1 (370mg) or Chromosorb 106 (285 mg) passive sampler 690-101
690-103
Other Passive GC-FID 575-001
Other Passive GC-FID 575-002
Other Passive TD, GC 690-101
690-103
Other Passive GC-FID 690-105
690-300
Other Passive DR 810-132D
Other Internal Passive TD, GC 690-101
690-103
Other Internal Passive GC-FID 690-105
690-300

Methods and limits as published by their agencies and summarised by SKC; check the current method and the limit that applies to you before sampling.