Hazard search
Tobacco smoke, environmental
- CAS number
- No CAS number
- Also known as
- Environmental tobacco smoke (nicotine & 3-ethenylpyridine)
UK workplace exposure limits
Our data hold no UK limit for this substance.
Sampling methods
| Method | Sampling | Medium | Analysis | Part numbers |
|---|---|---|---|---|
| ASTM D5075 Nicotine & 3-Ethenylpyridine by GC-NPD Method document (opens in a new tab) | Active (pump) | XAD-4 tube (80/40mg) | 226-93 | |
| ASTM D5955 Environmental Tobacco Smoke contribution to respirable particles by HPLC Method document (opens in a new tab) | Active (pump) | 37mm, 1µm PTFE filter | 225-3705 225-3LF 225-01-02 225-1 | |
| ASTM D6271 Environmental Tobacco Smoke (based on Solanesol) by HPLC/UV Method document (opens in a new tab) | Active (pump) | 37mm, 1µm PTFE filter | 225-3705 225-3LF 225-01-02 225-1 | |
| Non-agency 49 | Active (pump) | GC-NSD | 226-170 |
Methods and limits as published by their agencies and summarised by SKC; check the current method and the limit that applies to you before sampling.
Source: SKC Ltd (UK), Hazard Search, used with SKC's permission (opens in a new tab); SKC Inc. (USA), Sampling Guides, used with SKC's permission (opens in a new tab)