Hazard search

Tetrahydrofuran

CAS number
109-99-9
Also known as
1,4-Epoxybutane · Tetrahydrofuran (see online Passive Sampling Guide)

UK workplace exposure limits

LimitValueApplies to
8-hour TWA 50 ppm
8-hour TWA 150 mg/m³
15-minute STEL 100 ppm
15-minute STEL 300 mg/m³

Notations

  • Sk: can be absorbed through the skin

Sampling methods

MethodSamplingMedium AnalysisPart numbers
MDHS 88 Passive GC-FID 575-001
MDHS 88
VOCs by solvent desorption and GC
Method document (opens in a new tab)
Passive Passive sampler 575-002
MDHS 96
VOCs by solvent desorption and GC
Method document (opens in a new tab)
Active (pump) Charcoal tube (100/50mg) GC-FID 226-01
NIOSH 1609
Tetrahydrofuran by GC-FID
Method document (opens in a new tab)
Active (pump) Charcoal tube (100/50mg) GC-FID 226-01
Non-agency
Tetrahydrofuran by Colorimetric analysis
Direct-reading Gastec detector tube 810-159
810-161
Non-agency
VOCs by solvent extraction and GC
Method document (opens in a new tab)
Passive Anasorb CSC (500mg) passive sampler 690-105
Non-agency
VOCs by thermal desorption and GC
Method document (opens in a new tab)
Passive Anasorb GBC1 (370mg) or Chromosorb 106 (285 mg) passive sampler 690-101
690-103
Other Passive GC-FID 575-001
575-002
Other Passive TD, GC 690-101
690-103
Other Passive GC-FID 690-105
Other Internal Passive TD, GC 690-101
690-103
Other Internal Passive GC-FID 690-105

Methods and limits as published by their agencies and summarised by SKC; check the current method and the limit that applies to you before sampling.