Hazard search

Tetrachloroethylene

CAS number
127-18-4
Also known as
1,1,2,2-Tetrachloroethylene · Perchloroethylene · Perchloroethylene (tetrachloroethylene) · Perchloroethylene (tetrachloroethylene) (hydrocarbons, halogenated) · Perchloroethylene (tetrachloroethylene) (portable GC) · Perchloroethylene (tetrachloroethylene) (see online Passive Sampling Guide) · Tetrachloroethene · Tetrachloroethylene (hydrocarbons, halogenated) · Tetrachloroethylene (perchloroethylene) · Tetrachloroethylene (perchloroethylene) (portable GC)

UK workplace exposure limits

LimitValueApplies to
8-hour TWA 20 ppm
8-hour TWA 138 mg/m³
15-minute STEL 40 ppm
15-minute STEL 275 mg/m³

Notations

  • Sk: can be absorbed through the skin

Sampling methods

MethodSamplingMedium AnalysisPart numbers
MDHS 72
VOCs by thermal desorption and GC
Method document (opens in a new tab)
Active (pump) Tenax thermal desorption tube (250mg) TD, GC 226-357
MDHS 80 Active (pump) TD, GC 226-357
MDHS 88
VOCs by solvent desorption and GC
Method document (opens in a new tab)
Passive Passive sampler GC-FID 575-001
575-002
MDHS 96
VOCs by solvent desorption and GC
Method document (opens in a new tab)
Active (pump) Charcoal tube (100/50mg) GC-FID 226-01
MDHS 104
VOCs by solvent desorption and GC
Method document (opens in a new tab)
Active (pump) Charcoal tube (100/50mg) 226-01
MDHS 104
VOCs by thermal desorption and GC
Method document (opens in a new tab)
Active (pump) Tenax TD tube (250mg) 226-357
NIOSH 1003
Halogenated hydrocarbons by GC-FID
Method document (opens in a new tab)
Active (pump) Charcoal tube (100/50mg) GC-FID 226-01
NIOSH 3704 Active (pump) P GC 232-01
249-01-PP
NIOSH 3704
Perchloroethylene in exhaled air by portable GC -PID
Method document (opens in a new tab)
Active (pump) Sample bag with breath gas fitting 239-01
239-03
OSHA 1001
Tetrachloroethylene & Trichloroethylene by GC-FID
Method document (opens in a new tab)
Active (pump) Charcoal tube (100/50mg) GC-FID 226-01
OSHA 1001
Tetrachloroethylene & Trichloroethylene by GC-FID
Method document (opens in a new tab)
Passive Passive sampler GC-FID 575-002
OSHA 5000
Organic Vapour Sampling Group 1 by GC-FID
Method document (opens in a new tab)
Active (pump) Anasorb CSC sorbent tube 226-01
ASTM D5466
VOCs by GC -MS
Method document (opens in a new tab)
Active (pump) Canister GC-MS
EPA IP-1B
VOCs by thermal desorption and GC
Method document (opens in a new tab)
Passive Passive sampler 690-101
690-102
EPA TO-17 Active (pump) TD, GC 226-350
226-347
224-26-02
224-26-CPC
EPA TO-17
VOCs by thermal desorption and GC
Method document (opens in a new tab)
Active (pump) Two Thermal Desorption tubes
EPA TO-17
Toxic Organic Compounds by thermal desorption and GC
Method document (opens in a new tab)
Passive Passive sampler
Non-agency
Perchloroethylene by Colorimetric analysis
Direct-reading Gastec detector tube 810-133
Non-agency
VOCs by solvent extraction and GC
Method document (opens in a new tab)
Passive Anasorb CSC (500mg) passive sampler 690-105
Non-agency
VOCs by thermal desorption and GC
Method document (opens in a new tab)
Passive Anasorb GBC1 (370mg) or Chromosorb 106 (285 mg) or Tenax TA (265 mg) passive sampler 690-101
690-103
690-104
Non-agency
VOCs by thermal desorption and GC
Method document (opens in a new tab)
Passive Anasorb GBC1 (370mg) or Chromosorb 106 (285 mg) or Tenax TA (265 mg) passive sampler with rate reducer 690-101
690-103
690-104
690-300
Other Passive GC-FID 575-001
Other Passive GC-FID 575-002
Other Passive TD, GC 690-101
690-103
690-104
690-300
Other Passive GC-FID 690-105
Other Passive DR 810-132D
Other Passive DR 810-133D
Other Indoor Passive TD, GC 690-101
690-103
690-104
Other Internal Passive TD, GC 690-101
690-103
690-104
690-300
Other Internal Passive GC-FID 690-105

Methods and limits as published by their agencies and summarised by SKC; check the current method and the limit that applies to you before sampling.

Source: SKC Ltd (UK), Hazard Search, used with SKC's permission (opens in a new tab); SKC Inc. (USA), Sampling Guides, used with SKC's permission (opens in a new tab)