Hazard search
tert-Butyl acetate
- CAS number
- 540-88-5
- Also known as
- 1,1-Dimethylethanol acetate · 1,1-Dimethylethyl acetate · t-Butyl acetate · t-Butyl acetate (Esters I)
UK workplace exposure limits
| Limit | Value | Applies to |
|---|---|---|
| 8-hour TWA | 200 ppm | |
| 8-hour TWA | 966 mg/m³ | |
| 15-minute STEL | 250 ppm | |
| 15-minute STEL | 1210 mg/m³ |
Sampling methods
| Method | Sampling | Medium | Analysis | Part numbers |
|---|---|---|---|---|
| MDHS 72 VOCs by thermal desorption and GC Method document (opens in a new tab) | Active (pump) | Chromosorb 106 thermal desorption tube (300mg) | TD, GC | 226-358 |
| MDHS 88 VOCs by solvent desorption and GC Method document (opens in a new tab) | Passive | Passive sampler | GC-FID | 575-001 575-002 |
| MDHS 104 VOCs by solvent desorption and GC Method document (opens in a new tab) | Active (pump) | Charcoal tube (100/50mg) | 226-01 | |
| MDHS 104 VOCs by thermal desorption and GC Method document (opens in a new tab) | Active (pump) | Chromosorb 106 tube (300mg) | 226-358 | |
| NIOSH 1450 Esters by GC-FID Method document (opens in a new tab) | Active (pump) | Charcoal tube (100/50mg) | GC-FID | 226-01 |
| OSHA 1009 n-, Iso-, sec-, and tert-Butyl acetate by GC-FID Method document (opens in a new tab) | Active (pump) | Charcoal tube (100/50mg) | GC-FID | 226-01 |
| OSHA 1009 n-, Iso-, sec-, and tert-Butyl acetate by GC-FID Method document (opens in a new tab) | Passive | Passive sampler | GC-FID | 575-002 |
| OSHA 5000 Organic Vapour Sampling Group 1 by GC-FID Method document (opens in a new tab) | Active (pump) | Anasorb CSC sorbent tube | 226-01 | |
| EPA TO-17 | Active (pump) | TD, GC | 226-350 226-347 224-26-02 224-26-CPC | |
| EPA TO-17 VOCs by thermal desorption and GC Method document (opens in a new tab) | Active (pump) | Two Thermal Desorption tubes | ||
| EPA TO-17 Toxic Organic Compounds by thermal desorption and GC Method document (opens in a new tab) | Passive | Passive sampler | ||
| Other | Passive | GC-FID | 575-001 | |
| Other | Passive | GC-FID | 575-002 |
Methods and limits as published by their agencies and summarised by SKC; check the current method and the limit that applies to you before sampling.
Source: SKC Ltd (UK), Hazard Search, used with SKC's permission (opens in a new tab); SKC Inc. (USA), Sampling Guides, used with SKC's permission (opens in a new tab)