UK workplace exposure limits
| Limit | Value | Applies to |
|---|---|---|
| 8-hour TWA | 0.08 mg/m³ |
Sampling methods
| Method | Sampling | Medium | Analysis | Part numbers |
|---|---|---|---|---|
| MDHS 14/4 General inhalable or respirable dusts by gravimetric analysis (respirable) Method document (opens in a new tab) | Active (pump) | IOM & foam (or cyclone) with PVC filter | GR | 225-70A 225-772 225-69 225-5-25 |
| NIOSH 600 Particulates not otherwise regulated (respirable) by Gravimetric analysis Method document (opens in a new tab) | Active (pump) | Cyclone & 5µm PVC filter in cassette | 225-01-02 225-5-37-P 225-3LF 225-1 | |
| OSHA ID 142 |
Methods and limits as published by their agencies and summarised by SKC; check the current method and the limit that applies to you before sampling.