Hazard search

Propylene oxide

CAS number
75-56-9
Also known as
1,2-Epoxypropane · 1,2-Epoxypropane (see propylene oxide) · Methyl ethylene oxide · Methyloxirane · Propene oxide · Propylene oxide (1, 2-epoxypropane) · Propylene oxide (1, 2-epoxypropane) (see online Passive Sampling Guide)

UK workplace exposure limits

LimitValueApplies to
8-hour TWA 1 ppm
8-hour TWA 2.4 mg/m³

Notations

  • Carc: carcinogen

Sampling methods

MethodSamplingMedium AnalysisPart numbers
MDHS 72
VOCs by thermal desorption and GC
Method document (opens in a new tab)
Active (pump) Tenax thermal desorption tube (250mg) TD, GC 226-357
MDHS 80 Passive GC-FID 575-001
MDHS 88
VOCs by solvent desorption and GC
Method document (opens in a new tab)
Passive Passive sampler GC-FID 575-001
575-002
MDHS 96
VOCs by solvent desorption and GC
Method document (opens in a new tab)
Active (pump) Charcoal tube (100/50mg) GC-FID 226-01
MDHS 104
VOCs by thermal desorption and GC
Method document (opens in a new tab)
Active (pump) Chromosorb 106 tube (300mg) 226-358
NIOSH 1612
Propylene oxide by GC-FID
Method document (opens in a new tab)
Active (pump) Charcoal tube (100/50mg) GC-FID 226-01
OSHA 88
Propylene oxide by GC-FID
Method document (opens in a new tab)
Active (pump) Anasorb 747 tube (140/70) GC-FID 226-81A
Non-agency
Propylene oxide by Colorimetric analysis
Direct-reading Gastec detector tube 810-163
810-163L
Other Passive GC-FID 575-001
Other Passive GC-FID 575-002

Methods and limits as published by their agencies and summarised by SKC; check the current method and the limit that applies to you before sampling.

Source: SKC Ltd (UK), Hazard Search, used with SKC's permission (opens in a new tab); SKC Inc. (USA), Sampling Guides, used with SKC's permission (opens in a new tab)