Hazard search

Platinum metal

CAS number
7440-06-4
Also known as
Platinum · Platinum (as Pt), metal · Platinum (as Pt), soluble salts · Platinum (Elements by ICP HNO3 Digestion) · Pt

UK workplace exposure limits

LimitValueApplies to
8-hour TWA 5 mg/m³

Sampling methods

MethodSamplingMedium AnalysisPart numbers
MDHS 91/2
Metals & metalloids by XRF
Method document (opens in a new tab)
Active (pump) IOM or cyclone with 0.8µm MCE filter 225-70A
225-1930
NIOSH 7303
Elements by ICP (Hot block/HCl/HNO3 Digestion)
Method document (opens in a new tab)
Active (pump) 0.8µm MCE filter in 37mm cassette ICP-AES 225-3-01
225-1
OSHA ID 121 Active (pump) AA or AES 225-3-01
225-1
OSHA ID 130SG Active (pump) AA 225-3-01
225-1
OSHA ID-121
Metal & metalloid particulates by AAS
Method document (opens in a new tab)
Active (pump) 0.8µm MCE filter in cassette 225-3-01
225-1
OSHA ID-130SG
Platinum by AAS -GF
Method document (opens in a new tab)
Active (pump) 0.8µm MCE filter in 37mm cassette 225-3-01
225-1
BS ISO 15202-1:2020
Metals and Metalloids by ICP -AES
Method document (opens in a new tab)
Active (pump) IOM with 0.8µm MCE filter 225-70A
225-1930

Methods and limits as published by their agencies and summarised by SKC; check the current method and the limit that applies to you before sampling.