Hazard search
Platinum compounds, soluble, as Pt
- CAS number
- No CAS number
- Also known as
- Pt
UK workplace exposure limits
| Limit | Value | Applies to |
|---|---|---|
| 8-hour TWA | 0.002 mg/m³ |
Sampling methods
| Method | Sampling | Medium | Analysis | Part numbers |
|---|---|---|---|---|
| MDHS 91/2 Metals & metalloids by XRF Method document (opens in a new tab) | Active (pump) | IOM with 0.8µm MCE filter | 225-70A 225-1930 | |
| NIOSH 7303 Elements by ICP (Hot block/HCl/HNO3 Digestion) Method document (opens in a new tab) | Active (pump) | 0.8µm MCE filter in 37mm cassette | 225-3-01 225-1 | |
| OSHA ID-121 Metal & metalloid particulates by AAS Method document (opens in a new tab) | Active (pump) | 0.8µm MCE filter in cassette | 225-3-01 225-1 | |
| OSHA ID-130SG Platinum by AAS -GF Method document (opens in a new tab) | Active (pump) | 0.8µm MCE filter in 37mm cassette | 225-3-01 225-1 | |
| BS ISO 15202-1:2020 Metals and Metalloids by ICP -AES | Active (pump) | IOM with 0.8µm MCE filter | 225-70A 225-1930 |
Methods and limits as published by their agencies and summarised by SKC; check the current method and the limit that applies to you before sampling.
Source: SKC Ltd (UK), Hazard Search, used with SKC's permission (opens in a new tab)