UK workplace exposure limits
| Limit | Value | Applies to |
|---|---|---|
| 15-minute STEL | 0.2 ppm | |
| 15-minute STEL | 0.4 mg/m³ |
Sampling methods
| Method | Sampling | Medium | Analysis | Part numbers |
|---|---|---|---|---|
| OSHA ID 214 | Active (pump) | IC | 225-9014 | |
| OSHA ID-214 Ozone by IC Method document (opens in a new tab) | Active (pump) | Coated glass fibre filter in 37mm cassette (with oxidizer pretube if SO2 is present) | IC | 225-9014 225-1 |
| Non-agency Ozone by Colorimetric analysis | Direct-reading | Gastec detector tube | 810-18M 810-18L | |
| Other | Passive | DR | 526-300 |
Methods and limits as published by their agencies and summarised by SKC; check the current method and the limit that applies to you before sampling.