Hazard search

Molybdenum (insoluble)

CAS number
7439-98-7
Also known as
Mo · Molybdenum (Elements by Cellulosic Internal Capsule Sampler) · Molybdenum (Elements by ICP Aqua Regia Ashing) · Molybdenum (Elements by ICP HNO3 Digestion) · Molybdenum (Elements by ICP HNO3/HClO4 Ashing) · Molybdenum (Elements on Wipes) · Molybdenum (soluble) · Molybdenum compounds (insoluble) (as Mo) · Molybdenum compounds (soluble) (as Mo) · Molybdenum insolubles (as Mo) · Molybdenum insolubles (as Mo) (respirable fraction) · Molybdenum solubles (as Mo)

UK workplace exposure limits

LimitValueApplies to
8-hour TWA 10 mg/m³ Molybdenum (insoluble)
15-minute STEL 20 mg/m³ Molybdenum (insoluble)
8-hour TWA 5 mg/m³ Molybdenum (soluble)
15-minute STEL 10 mg/m³ Molybdenum (soluble)

Sampling methods

MethodSamplingMedium AnalysisPart numbers
MDHS 91/2
Metals & metalloids by XRF
Method document (opens in a new tab)
Active (pump) IOM or cyclone with 0.8µm MCE filter XRF 225-70A
225-1930
NIOSH 7300
Elements by ICP (Nitric/perchloric acid ashing)
Method document (opens in a new tab)
Active (pump) 0.8µm MCE filter or 5µm PVC filter in 37mm cassette ICP-AES 225-3-01
225-1
NIOSH 7301
Elements by ICP (Aqua regia ashing)
Method document (opens in a new tab)
Active (pump) 0.8µm MCE filter or 5µm PVC filter in 37mm cassette ICP-AES 225-3-01
225-1
225-803
NIOSH 7303
Elements by ICP (Hot block/HCl/HNO3 Digestion)
Method document (opens in a new tab)
Active (pump) 0.8µm MCE filter in 37mm cassette ICP-AES 225-3-01
225-1
NIOSH 7306
Elements by Cellulosic Internal Capsule Sampler ICP -AES
Method document (opens in a new tab)
Active (pump) Solu-CAP MCE Filters Preloaded in Cassettes and Cassette Holder ICP-AES 225-8517
225-1
NIOSH 9102
Elements on wipes by ICP -AES
Method document (opens in a new tab)
Surface Wipe ICP-AES 225-2414
225-2415
OSHA 125G
Metals & metalloid particulates by ICP
Method document (opens in a new tab)
Active (pump) 0.8µm MCE filter with back-up pads 225-3-01
225-1
OSHA ID 121 Active (pump) AA or AES 225-3-01
225-1
225-503
225-105
OSHA ID 125G Active (pump) ICP-AES 225-3-01
225-3100
225-1
OSHA ID-121
Metal & metalloid particulates by AAS
Method document (opens in a new tab)
Active (pump) 0.8µm MCE filter with back-up pads 225-3-01
225-1
OSHA ID-204
Workplace Substances by X-Ray Fluorescence
Method document (opens in a new tab)
Active (pump) MCE or PVC filters in cassette
BS ISO 15202-1: 2020
Determination of metals and metalloids in airborne particulate matter by IC
Active (pump) IOM with 0.8µm MCE filter 225-70A
225-1930
BS ISO 15202-1: 2020
Determination of metals and metalloids in airborne particulate matter by ICP
Active (pump) IOM with 0.8µm MCE filter 225-70A
225-1930

Methods and limits as published by their agencies and summarised by SKC; check the current method and the limit that applies to you before sampling.

Source: SKC Ltd (UK), Hazard Search, used with SKC's permission (opens in a new tab); SKC Inc. (USA), Sampling Guides, used with SKC's permission (opens in a new tab)