Hazard search

Isobutanol

CAS number
78-83-1
Also known as
2-Methyl-1-propanol · 2-Methylpropan-1-ol · Isobutanol (isobutyl alcohol) · Isobutyl alcohol · Isobutyl alcohol (alcohols combined) · Isobutyl alcohol (alcohols II) · Isobutyl alcohol (isobutanol) · Isobutyl alcohol (see online Passive Sampling Guide) · Isopropyl carbinol

UK workplace exposure limits

LimitValueApplies to
8-hour TWA 50 ppm
8-hour TWA 154 mg/m³
15-minute STEL 75 ppm
15-minute STEL 231 mg/m³

Sampling methods

MethodSamplingMedium AnalysisPart numbers
MDHS 72
VOCs by thermal desorption and GC
Method document (opens in a new tab)
Active (pump) Tenax (250mg) or Chromosorb 106 (300mg) thermal desorption tube TD, GC 226-357
226-358
MDHS 80
VOCs by thermal desorption and GC
Method document (opens in a new tab)
Passive Chromosorb 106 thermal desorption tube (350mg) with diffusive end caps 226-358
MDHS 88
VOCs by solvent desorption and GC
Method document (opens in a new tab)
Passive Passive sampler GC-FID 575-001
575-002
MDHS 96
VOCs by solvent desorption and GC
Method document (opens in a new tab)
Active (pump) Charcoal tube (100/50mg) GC-FID 226-01
MDHS 104
VOCs by solvent desorption and GC
Method document (opens in a new tab)
Active (pump) Charcoal tube (100/50mg) 226-01
MDHS 104
VOCs by thermal desorption and GC
Method document (opens in a new tab)
Active (pump) Tenax TA (250mg) or chromosorb 106 (300mg) TD tube 226-357
226-358
NIOSH 1401
Alcohols by GC-FID
Method document (opens in a new tab)
Active (pump) Charcoal tube (100/50mg) GC-FID 226-01
NIOSH 1405
Alcohols (combined) by GC-FID
Method document (opens in a new tab)
Active (pump) Charcoal tube (100/50mg) GC-FID 226-01
OSHA 5001
Organic Vapor Sampling Group 2 by GC-FID
Method document (opens in a new tab)
Active (pump) Set of two Anasorb 747 tubes (400mg & 200mg) GC-FID 226-82
222-3L-1
EPA TO-17
VOCs by thermal desorption and GC
Method document (opens in a new tab)
Active (pump) Two Thermal Desorption tubes TD, GC 226-350
226-347
224-26-02
224-26-CPC
Non-agency
Isobutyl alcohol by Colorimetric analysis
Direct-reading Gastec detector tube 810-116
Other Passive GC-FID 575-001
Other Passive GC-FID 575-002

Methods and limits as published by their agencies and summarised by SKC; check the current method and the limit that applies to you before sampling.

Source: SKC Ltd (UK), Hazard Search, used with SKC's permission (opens in a new tab); SKC Inc. (USA), Sampling Guides, used with SKC's permission (opens in a new tab)