Ferrous foundry particulate (respirable)
- CAS number
- No CAS number
- Also known as
- FFP
UK workplace exposure limits
| Limit | Value | Applies to |
|---|---|---|
| 8-hour TWA | 4 mg/m³ |
Sampling methods
| Method | Sampling | Medium | Analysis | Part numbers |
|---|---|---|---|---|
| MDHS 14/4 General inhalable or respirable dusts by gravimetric analysis (respirable) Method document (opens in a new tab) | Active (pump) | IOM + foam (or cyclone) with GF filter | 225-70A 225-772 225-69 225-58F |
Methods and limits as published by their agencies and summarised by SKC; check the current method and the limit that applies to you before sampling.
Source: SKC Ltd (UK), Hazard Search, used with SKC's permission (opens in a new tab)