Hazard search

Dodecane

CAS number
112-40-3
Also known as
n-Dodecane

UK workplace exposure limits

Our data hold no UK limit for this substance.

Sampling methods

MethodSamplingMedium AnalysisPart numbers
MDHS 72
VOCs by thermal desorption and GC
Method document (opens in a new tab)
Active (pump) Tenax TD tube (250mg) 226-357
MDHS 104
VOCs by solvent desorption and GC
Method document (opens in a new tab)
Active (pump) Charcoal tube (100/50mg) 226-01
MDHS 104
VOCs by thermal desorption and GC
Method document (opens in a new tab)
Active (pump) Tenax TD tube (250mg) 226-357
NIOSH 1500
Hydrocarbons (BP 36-216°C) by GC-FID
Method document (opens in a new tab)
Active (pump) Charcoal tube (100/50mg) 226-01
EPA TO-17
VOCs by thermal desorption and GC
Method document (opens in a new tab)
Active (pump) Two Thermal Desorption tubes TD, GC 226-350
226-347
224-26-02
224-26-CPC
Non-agency
VOCs by solvent desorption and GC-FID
Method document (opens in a new tab)
Passive Passive sampler 575-001
575-002

Methods and limits as published by their agencies and summarised by SKC; check the current method and the limit that applies to you before sampling.